My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2021 8:50:52 AM
Creation date
3/25/2021 8:52:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SPILL CONTAINER TESTING REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Test ❑Repair Test Z 12 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Spill Container Test <br /> 10181491 9/29/2020 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> MARKS FUEL & FOOD, INC <br /> Business Site Address City ZIP Code <br /> 880 E VICTOR ROAD LODI, CA 95240 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the/CC Certification.) Phone# <br /> ZANE NIMMO (209) 744-0112 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 04-1676 Ex. 3/31/22 8883064-UT 6/1/2021 <br /> Spill Container Testing Training and Certifications(List applicable certifications.) <br /> Franklin Fueling - EBW& Phil Tite #10009843708 Ex.11/29/2020 <br /> OPW#104-632 Ex. 3/15/2022 <br /> III. SPILL CONTAINER TESTING INFORMATION <br /> Test Method Used: ❑x Manufacturer Guidelines(Specify): O P W PHASE I LAKE TESTING <br /> ❑ Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the testing procedures and all documentation required to determine the results. #of Attached Pages <br /> TANK ID: (By tank number,stored product,etc.) 87 OCTANE 91 OCTANE DIESEL # 2 <br /> Spill Container Manufacturer: O P W O P W O P W <br /> Method of Cathodic Protection: ❑x Non-Metallic 0 Non-Metallic ❑x Non-Metallic ❑Non-Metallic <br /> ❑ Isolation ❑ Isolation ❑ Isolation ❑ Isolation <br /> ❑Other(Specify in V.) ❑ Other(Specify in V.) ❑Other(Specify in V.) ❑Other(Specify in V.) <br /> Inside Diameter of Spill Container: (Inches) 11 1/2 11 1/2 11 1/2 <br /> Depth of Spill Container: (Inches) 13 13 1/2 13 <br /> Does the spill container have a 5 gallon capacity? ❑x Yes ❑ No ❑x Yes ❑ No Z Yes ❑No ❑Yes ❑No <br /> Method to Keep Spill Container Empty: Z Drain Valve 0 Drain Valve 0 Drain Valve ❑Drain Valve <br /> ❑Onsite Pump ❑Onsite Pump ❑Onsite Pump ❑Onsite Pump <br /> ❑Other(Specify in V.) ❑Other(Specify in V.) ❑Other(Specify in V.) ❑Other(Specify in V.) <br /> IV. SUMMARY OF TESTING RESULTS <br /> Spill Container Test Results: Z Pass ❑Fail ❑x Pass ❑Fail ❑x Pass ❑ Fail ❑Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked"Fail'above must be explained in this section. Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the spill containers were tested in accordance with California Code of Regulations, Title 23, Division 3, <br /> Chapter 16,Section 2637.1 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council <br />
The URL can be used to link to this page
Your browser does not support the video tag.