Laserfiche WebLink
Certificate Number:02-019A24 <br /> Page 2 of 19 <br /> Gilbarco,Inc. <br /> Retail Motor Fuel Dispenser(RMFD)/Nxx Series <br /> Application: For use in dispensing standard fuels such as gasoline, gasoline with up to 15% ethanol and gasoline with up to 15% <br /> methanol blend types and diesel fuel,fuel oil,kerosene and up to 20%biodiesel products as indicted in Section C. "Product Families <br /> for Meters" table in NCWM Publication 14,Measuring Devices at retail service stations, attended or unattended,with approved and <br /> compatible equipment.Units equipped with the T19976-GX or V3 meter are additionally rated for up to E25.Units equipped with the <br /> Gilbarco T9796 G5 meter are additionally approved for dispensing alternate fuels such as gasoline with greater than 25%Ethanol and <br /> diesel with greater that 20%biodiesel(i.e.up to 100%Ethanol and 100%Bio-diesel).The Ultra High series with the LC M5 meter are <br /> approved to dispense gasoline and diesel fuels. These dispensers are approved for use with Phase E vapor recovery equipment and <br /> approved booted or bootless nozzles when the system and components are certified and comply with the zero-set-back interlock <br /> requirements.Gilbarco self-contained dispensers(unit with a pump and a motor)are provided with onboard automatic air elimination. <br /> Gilbarco remote dispensers(units do not have motor and pump)require the use of a remotely located pump. These remote dispensers <br /> require automatic air elimination at the remote pump/STP,or the use of a low product cut off that will prevent air from entering the <br /> pump if the fluid level in the tank falls below a point that air could be ingested into the system or the use of other automatic means to <br /> prevent air from entering the system. <br /> Identification: The identification badge,metal or a self-destructive badge is on the lower base plate below the access panel covering <br /> the hydraulics cabinet or located behind the locked main options door.Optional features are indicated on the identification plate. <br /> Sealin : The Encore Series device has no remote configuration capability and is classified as a Category 2 device. Access to all <br /> metrological features and functions are controlled through the use of a sealable security switch. The security switch has two positions, <br /> "normal/sealed" and "calibration/configuration." When the security switch is in the "calibration/configuration" position, sealable <br /> parameters including meter calibration,gallon/liter settings,and blend ratio settings can be accessed.Access to sealable parameters is <br /> prevented by placing the security switch in the "normal/sealed" position and threading a wire security seal through the cover,which <br /> fits over the security switch.The wire security seal must be broken in order to lift the hinged cover and to move the security switch to <br /> the "calibration/configuration" position. The security switch and Manager's keypad are located behind the locked main options door. <br /> Access to the security switch and Manager's keypad requires opening the options door. Due to security concerns and theft issues, <br /> many stations have removed the Manager's Keypad from the unit. W&Ms officials may need to contact station personnel to obtain <br /> this keypad. Gilbarco will provide Manager's keypad(s)to each site. <br /> The Gilbarco T20453-GX ECO meter or M07300A001, M07300A002, M07300A003, M0730OA005 or M0730OA006 E-Meter <br /> Model (NTEP CC 02-040A3) is located in the side column, and does not have any adjustable or metrological calibration features. <br /> Gilbarco provides a factory installed, tamper evident decal/seal containing the Gilbarco Inc. name, Trademark or logo, and a non- <br /> repetitive serial number.(See Operation) <br /> Encore "S" series may also have a user provided lock that must be accessed. The locked lower hydraulics door must be removed to <br /> access the user provided lock.This locks a"tool box"type latch that secures the main door.To access features located behind the main <br /> door first remove the lower hydraulics door,then unlatch the main door's"tool box"latch,then open the main door. The main door is <br /> secured with a lock/key and the lock is located on the left side of the door. <br /> Electronic calibration (E-cal): Access to the electronic calibration feature is through the security switch described above. With the <br /> switch in the "calibration/configuration" position, a calibration code and the volume of the volumetric standard are entered into the <br /> keypad next to the security switch.Product is then dispensed into the standard,a delivery error is determined in cubic inches, and the <br /> error value is entered into the keypad. The security switch is then returned to the normal operating("normal/sealed")position and the <br /> switch cover is sealed with a wire security seal. <br /> Gallon/Liter setting: Access to the gallon/liter setting is through the security switch described above. With the switch in the <br /> "calibration/configuration" position, a conversion factor is used to program all Encore® Series dispensers to indicate in gallons or <br /> liters. Gallon/Liter setting information can also be viewed without entering the configuration mode. With the switch in the <br /> "normal/sealed" position, the number of times that the conversion factor has been changed since the initial installation can be <br /> displayed in the main"Volume" display by pressing "ENTER" on the manager's keypad. Press any other key to revert to the normal <br /> display.See"examples"shown below. <br /> Blend ratio setting:Access to the blend ratio setting is through the security switch described above.On customer-selectable and fixed- <br /> blenders,the individual blend ratios for each grade may be programmed at the dispenser. Blend ratio information can also be viewed <br />