GONE <br /> T[f <br /> Certificate Number:02-019A24 <br /> Page 17 of 19 <br /> "$ANO <br /> Gilbarco,Inc. <br /> Retail Motor Fuel Dispenser(RMFD)/Nxx Series <br /> Certificate of Conformance Number 00-035A2: This Certificate supersedes Certificate of Conformance Number 00-035A1 and is <br /> issued to reflect a change in the model's base electronics options. The new optional electronics in the Encore comes directly from the <br /> manufacturers Advantage Series, Certificate of Conformance Number 99-173. The model with the Advantage Series electronics <br /> option will be identified as Encore 300.The manufactures current Encore will be renamed Encore 500.For all models,Encore,Encore <br /> 500 and the new Encore 300,the Audit trail,Electronic totalizers and Electronic meter calibration remain the same as currently shown <br /> in this Certificate. This certificate also adds two new models NG4, Dispenser Single Hose, 2 Grade and NGS, Pump Single Hose,2 <br /> Grade to the model code section of this certificate. These models represent are same as previously evaluated models,minus one hose <br /> position, and does not represent a change that requires additional evaluation. This Certificate is issued based upon information <br /> provided by the manufacturer,the previous evaluation,and the evaluation of the manufacturers Advantage series.The units hydraulics <br /> section (Meters, valves, piping, filters, etc.) have not changed. Due to all components having active Certificates of Conformance, <br /> additional type evaluation or field permanence testing is not required. <br /> Certificate of Conformance Number 00-035A1: This Certificate supersedes Certificate of Conformance Number 00-035 and is <br /> issued to correct the method of sealing used in the device,to reflect the elimination of the event logger capability from the device,and <br /> to include additional information in the original test conditions. This Certificate is issued based upon information provided by the <br /> manufacturer,the previous evaluation,and an evaluation of the sealable features on a recently installed unit. <br /> An Encore Series dispenser was installed in a field site interfaced with a console for the purposes of this evaluation. The emphasis of <br /> the evaluation was on the method of accessing the sealable features on the device and the security provided to control access to the <br /> features.A summary of the changes to the Certificate as a result of the current evaluation are outlined below followed by the previous <br /> test conditions. <br /> The original Certificate incorrectly stated that the blend ratios can be configured at the device or remotely through the console. All <br /> sealable features, including the blend feature, are accessed only through a physical switch at the device, which is protected by a <br /> physical security seal. Because its sealable features cannot be accessed remotely,the device is categorized as a "Category 1" device. <br /> Access to these features is protected by a physical seal as described under "Sealing." The operation of the physical switch to access <br /> sealable parameters and the method of sealing that switch were evaluated in the original evaluation of the device. Additionally, the <br /> current operation of accessing and securing the sealable parameters was verified as described in the evaluation above. <br /> The original Certificate listed an "event logger"as a feature for providing information concerning changes to sealable parameters. An <br /> event logger is required for devices with unlimited remote access, that is, for "Category 3" devices. While the device originally <br /> evaluated included an event logger similar to that required in Category 3 devices,the device did not have unlimited remote access and <br /> an event logger was not required; the manufacturer chose to provide the event logger only as supplemental information. The <br /> manufacturer has now chosen to eliminate the event logger feature from the device.As a Category 1 device,the device does not have <br /> unlimited access to sealable parameters and an event logger is not required. The deletion of this feature was confirmed during the <br /> evaluation described above,and the Certificate has been modified accordingly. <br /> Certificate of Conformance Number 00-035: The emphasis of the evaluation of this device,generically known as the Encore Series, <br /> was on the operation and performance of the device. A unit was evaluated at the manufacturer's facility where more than 1,000,000 <br /> gallons of product were run through the device.Additionally,a unit was installed in a field installation where it was evaluated initially <br /> and again after 20 days to evaluate the operation of the electronics. Tests were conducted at both the field sites and laboratory for all <br /> options listed on page 1 of this Certificate. Additionally,the options listed on page 1 are identical to those evaluated in conjunction <br /> with Certificate of Conformance Number 90-115A9 for the Marconi(formerly Gilbarco)Advantage Series. <br /> Evaluated BY: R. Murdock, J. Butler, W. Scruton(NC) 00-035; R. Murdock, J. Butler(NC)00-035A1; J. Butler(NC), W. Scruton <br /> (NC) 02-019A2, 02-019A3; J. Butler (NC), 02-019A6; J. Butler, Katalinic (NC), 02-019A7, 02-019A8, 02-019A9, 02-019A10; J. <br /> Butler,B.Moore(NC),02-040A2;A.Katalinic(NC),02-019A13,02-019A14;J.Butler,Katalinic(NC),02-019A15;J.Butler(NC), <br /> Katalinic (NC) Rick LaMountain (NC) 02-019A16; J. Butler (NC), Katalinic (NC) 02-019A 17, 02-019A18; J. Butler (NC) <br /> 02-019A19,02-019A21;J.Butler,A.Katalinic(NC)02-019A22, 02-019A23;A.Katalinic(NC) 02-019A24 <br /> Type Evaluation Criteria Used: MST, Handbook 44: Specifications, Tolerances and Other Technical Requirements for Weighing <br /> and Measurine Devices,2015.NCWM,Publication 14:Measuring Devices,2015. <br />