Laserfiche WebLink
Geosyntec° <br /> Geosymtec° cnnsultants <br /> consultants 4. SCOPE OF WORK <br /> engineers I scientists I innovators 4.1 Rationale and Approach <br /> The Supplemental Guidance recommends a four-step evaluation process for conducting VI <br /> evaluations.The four steps consist of the following: <br /> VAPORINTRUSION PILOT STUDY 1. Prioritizing buildings in the proximity to source contamination for a VI assessment <br /> 2. Collect exterior soil vapor samples to determine if buildings have potential for VI <br /> WORKPLAN 3. Collecting indoor air,sub-slab soil vapor and outdoor air samples if buildings have <br /> potential VI risks <br /> LINCOLN CENTER, 4. Evaluating the need to manage current and future VI risk based on both indoor air <br /> concentrations and soil vapor concentrations <br /> STOCKTON, CALIFORNIA The scope of work has been developed to follow the stepwise approach recommended by the <br /> Supplemental Guidance. <br /> There are two areas proposed for additional investigation activities:1)A vacant suite located at <br /> 858 West Benjarnin Holt Drive,and 2)an occupied suite located at 240 Lincoln Center(Figure <br /> Prepared for 2).These suites are located on-Site,in the Lincoln Center Shopping Center.The vacant suite is <br /> Lincoln Center Environmental Remediation Trust located near the former source area where some of the more elevated PCE impacts have been <br /> 3043 Gold Canal Drive,Suite 100 observed in shallow groundwater.This suite is located near the location where recent ISCO <br /> Rancho Cordova,California 95670 injection activities have occurred along West Benjamin Holt Drive,as described in Section 2.4. <br /> The occupied suite is located north of the main former source area where PCE impacts to <br /> Prepared by shallow groundwater have been observed to be slightly elevated.This suite is located north of <br /> West Benjamin Holt Drive,away from the recent ISCO injections and known soil source.In <br /> Geosyntec Consultants,Inc. accordance with the Step I of the Supplemental Guidance,these locations were selected because <br /> 3043 Gold Canal Drive,Suite 100 of their proximity to the potential sources of VI. <br /> Rancho Cordova,California 95670 <br /> The Supplemental Guidance recommends the collection of exterior soil vapor samples,indoor <br /> Project Number:SAC 1 I I H air,sub-slab soil vapor,and outdoor air samples to evaluate the VI potential(Step 2 and 3).This <br /> data can also be used to develop site-specific attenuation factors.Collocated groundwater and <br /> April 2020 soil vapor samples will be collected from the two study areas.In addition,a paired sub-slab soil <br /> vapor samples and indoor samples will be collected to develop building-specific attenuation <br /> factors.The two proposed locations for this study have in-part been selected because elevated <br /> concentrations of VOCs have been reported in monitoring wells screened where first <br /> encountered groundwater is present during recent sampling events.These areas are therefore <br /> anticipated to have the greatest potential for vapor intrusion at the Site. <br /> .,� According to the 2011 DTSC Guidance for the Evaluation and Mitigation of Subsurface Vapor <br /> Intrusion to Indoor Air(Vapor Intrusion Guidance;DTSC,2011),it is recommended that <br /> © groundwater samples be collected from a permanent monitoring well that is screened across the <br /> top of water and the saturated thickness in the well should be 10 feet or less.Recent groundwater <br /> �4 x monitoring data(refer to Section 2.3.5)indicated the top of water elevation is approximately 10 <br /> feet msl.However,the aquifer is semi-confined,as noted in Section 2.3.1.Historical boring logs <br /> \\ � for monitoring wells in the areas of interest were reviewed to identify where saturated soils were <br /> 202003 Liu oln Center VI Pilot Study NP.dmx 9 April 2020 <br /> V <br /> �t <br />