Geosyntec Procedures: HS-115-Hazard Communication,HS-111-Air Monitoring,HS-112-Respiratory Protection, <br /> HS-113-Personal Protective Equipment,HS-114-Safety Training Programs, Others as applicable <br /> 6.14. SITE CONTAMINANTS,CHEMICAL WASTES ®Applicable ❑ Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> CHECK ALL THAT APPLY. Provide explanatory notes above. <br /> Z Soil/groundwater contaminants(historical release) ❑Oxygen deficiency ❑Corrosive,acids/caustics,strong irritants <br /> ❑Recent release,known high concentrations Z Chlorinated volatile organic compounds (VOCs) ❑Sulfides,hydrogen sulfide(H2S) <br /> ❑Former chemical disposal site,landfill BTEX,petroleum derived VOCs ❑Cyanides,hydrogen cyanide(HCN) <br /> Z Urban fill,residual contaminants ❑Fuel oils,petroleum,waste oil,lubricants ❑Asbestos <br /> ❑'Containerized waste(drums,process equipment) ❑Metals,metal compounds,metal dusts ❑Lead paint <br /> ❑Buried drums(known or potential) ❑Elemental mercury ❑Pesticides,herbicides,fungicides <br /> ❑Large containers,potential for spills ❑Polyaromatic hydrocarbons(PAHs) ❑Sensitizers <br /> Contaminated building surfaces —Polychlorinated biphenyls(PCBs) ❑Radioactive contaminants <br /> Unexploded ordnance ❑Potential for flammable vapors ❑Other(see Explanatory Notes,above) <br /> ❑Explosive dust ❑Potential for flammable gas(methane) <br /> ® FOR WORK CONSISTING OF CLEANUP OPERATIONS,CORRECTIVE ACTIONS,PRELIMINARY INVESTIGATIONS at an"UNCONTROLLED HAZ.WASTE SITE" <br /> (per HAZWOPER,29 CFR 1910.120),implement the following as applicable to the work: <br /> - Implement site control plan via Exclusion Zone(s),Contaminant Reduction Zone(s)and Support Zone(aka EZ,CRZ,SZ) <br /> - Workers to be aware of and trained on hazards per OSHA Hazard Communication Standard. <br /> - Include site map/figure depicting work locations and other relevant site-specific information. <br /> - Site workers in EZ or CRZ to have OSHA 40-hour training,current 8-hour refresher,3 days supervised field experience. <br /> - Site supervisor(s)required to have 8-hr.Supervisor training. <br /> - Site workers in EZ or CRZ to participate in Medical Monitoring program,as applicable. <br /> - Implement site-specific procedures for worker protection via engineering controls,work practices,personal protective equipment(PPE),air <br /> monitoring,decontamination procedures,spill containment,emergency preparedness and response. <br /> - Conduct air monitoring,as appropriate(see Part C,"Air Monitoring,Worker Exposure Monitoring"). <br /> IMPORTANT: Provide supplemental information to sufficiently detail site-specific procedures for the above elements,as appropriate for the work. <br /> Geosyntec Procedures:HS-301-HAZWOPER,HS-108-Medical Monitoring Surveillance,HS-111-Air Monitoring,HS-111-Respiratory Protection, <br /> HS-113-Personal Protective Equipment,HS-114-Safety Training Programs,HS-115-Hazord Communication,HS-405-Drum Sampling,Others as applicable <br /> FOR SITE WITH CHEMICAL CONTAMINANTS OR WASTE BUT NOT REGULATED BY HAZWOPER <br /> - Workers to be knowledgeable/aware of chemical hazards through safety training/orientation and availability of hazard information <br /> - Implement controls to minimize worker exposure through engineering controls,work practices,PPE,as appropriate. <br /> - Conduct air monitoring/sampling to monitor/evaluate worker exposure,as applicable. <br /> Geosyntec Procedures: HS-111-Air Monitoring,HS-112-Respiratory Protection,HS-113-Personal Protective Equipment, <br /> HS-114-Safety Training Programs,HS-115-Hazard Communication,Others as applicable <br /> OFF-SITE MIGRATION OF ❑Implement controls to minimize hazard migration(dust suppression,covers,foam,etc.) <br /> CONTAMINANTS ❑Community/perimeter air monitoring to be conducted per perimeter air monitoring plan. <br /> SPILL CONTAINMENT,CONTAINERS ❑Describe above any site-specific procedures for spill containment,container handling,as applicable. <br /> Geosyntec Procedures: HS-406-Unknown Hazardous Waste Drum Handling <br /> 13.15. RADIATION HAZARDS(Other than Sunlight) ❑ Applicable ® Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> IONIZING Describe hazards&safety measures above in Explanatory Notes,Clarifications. <br /> RADIATION Conduct exposure monitoring,as appropriate(see Part C,"Air Monitoring,Worker Exposure Monitoring"). <br /> Geosyntec Procedures: HS-126-Radiation Safety Program,HS-128-Ionizing and Non-Ionizing Radiation <br /> ❑ NON-IONIZING Describe hazards&safety measures above in Explanatory Notes,Clarifications. <br /> RADIATION Conduct exposure monitoring,as appropriate(see Part C,"Air Monitoring,Worker Exposure Monitoring"). <br /> Geosyntec Procedures: HS-118-Ionizing and Non-IonizingRodiation <br /> 13.16. HAZMATIDANGEROUS GOODS SHIPPINGITRANSPORTATION ❑ Applicable ® Not Applicable,Not Anticipated <br /> MODE(S)OF TRANSPORT: ❑Road ❑Rail ❑Air ❑Sea ❑Inland Waterway ❑International <br /> IMPORTANT:Ensure that each individual who will be involved in shipping/transportation of hazardous material is current with required training(awareness,function- <br /> specific,safety,security)in accordance with applicable regulatory authority(DOT,FAA,IATA,TDG),and ensure adherence to applicable regulations. <br /> Geosyntec Procedures: HS-135-Hazardous Materials Procedures <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> PART C-AIR MONITORING, WORKER EXPOSURE MONITORING <br /> Geosyntec° Lincoln Center-aSAC1111 Soil Vapor Probe Installation and Sampling October Pa,2020 <br /> ge 10 <br /> consultants <br />