My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WALNUT GROVE
>
9015
>
2300 - Underground Storage Tank Program
>
PR0521738
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 3:52:27 PM
Creation date
4/1/2021 8:55:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0521738
PE
2371
FACILITY_ID
FA0014762
FACILITY_NAME
JD Service Station, Inc.
STREET_NUMBER
9015
STREET_NAME
WALNUT GROVE
STREET_TYPE
RD
City
THORNTON
Zip
95686
CURRENT_STATUS
01
SITE_LOCATION
9015 WALNUT GROVE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LIQUID SENSOR SETUP OUTPUT RELAY SETUP ISD SITE ALARMS <br /> - - - - - - - - - _ - - - - - - - - - - - - - - ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL <br /> L 1 :DISP. 1 R 1 :67 STP ISD VAPOR LEAK FAIL <br /> TRI-STATE (SINGLE FLOAT) TYPE: ISD VP PRES FAIL <br /> CATEGORY : DISPENSER PAN STANDARD ISD VP STATUS FAIL <br /> NORMALLY CLOSED <br /> ISD HOSE ALARMS <br /> TANK #: 2 ALL:GROSS COLLECT FAIL <br /> L 2:DISP. 3-4 ALL:DEGRD COLLECT FAIL <br /> TRI-STATE (SINGLE FLOAT) ALL:FLOW COLLECT FAIL <br /> CATEGORY : DISPENSER PAN LIQUID SENSOR ALMS <br /> L 1 :FUEL ALARM R 3:DIESEL STP <br /> L 2:FUEL ALARM TYPE: <br /> L 3:FUEL ALARM STANDARD <br /> L 3:DISP. 5-6 L 4:FUEL ALARM NORMALLY CLOSED <br /> TRI-STATE (SINGLE FLOAT) L 5:FUEL ALARM <br /> CATEGORY, : DISPENSER PAN L 6:FUEL ALARM TANK #: 3 <br /> L14:FUEL ALARM <br /> L 1 :SENSOR OUT ALARM <br /> L 2:SENSOR OUT ALARM LIQUID SENSOR ALMS <br /> L 4:DISP. 7-8 L 3:SENSOR OUT ALARM L 3:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 4:SENSOR OUT ALARM L 5:FUEL ALARM <br /> CATEGORY DISPENSER PAN L 5:SENSOR OUT ALARM L 7:FUEL ALARM <br /> L 6:SENSOR OUT ALARM L 3:SENSOR OUT ALARM <br /> L14:SENSOR OUT ALARM L 5:SENSOR OUT ALARM <br /> L 1 :SHORT ALARM L 7:SENSOR OUT ALARM <br /> L 5:DISP. 9-10 L 2:SHORT ALARM L 3:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 3:SHORT ALARM L 5:SHORT ALARM <br /> CATEGORY DISPENSER PAN L 4:SHORT ALARM L 7:SHORT ALARM <br /> L 5:SHORT ALARM <br /> L 6:SHORT ALARM R 4:OVERFILL <br /> L14:SHORT ALARM TYPE: <br /> L 6:DISP. 11-12 STANDARD <br /> TRI-STATE (SINGLE FLOAT) ISD SITE ALARMS NORMALLY OPEN <br /> CATEGORY : DISPENSER PAN ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL TANK #: NONE <br /> ISP VAPOR LEAK FAIL <br /> ISD VP FRES FAIL <br /> L 7:DIESEL STP ISD VP STATUS FAIL IN-TANK ALARMS <br /> TRI-STATE (SINGLE FLOAT) ALL:OVERFILL ALARM <br /> CATEGORY : STP SUMP ISD HOSE ALARMS ALL:HIGH PRODUCT ALARM <br /> ALL:GROSS COLLECT FAIL ALL:MAX PRODUCT ALARM <br /> ALL:DEGRD COLLECT FAIL <br /> L 6:DIESEL FILL ALL:FLOW COLLECT FAIL <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : PIPING SUMP R 2:91 STP <br /> TYPE: <br /> 4STANDARD <br /> L 9:91 DIESEL ANNULAR NORMALLY CLOSED <br /> DUAL POINT HYDROSTATIC <br /> CATEGORY : ANNULAR SPACE TANK #: 1 <br /> LIQUID SENSOR ALMS <br /> 1_10:91 STP L 1 :FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 2:FUEL ALARM <br /> CATEGORY : STP SUMP L 3:FUEL ALARM <br /> L 4:FUEL ALARM <br /> L 5:FUEL ALARM <br /> L11 :91 FILL L 6:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L10:FUEL ALARM <br /> CATEGORY : PIPING SUMP L 1 :SENSOR OUT ALARM <br /> L 2:SEM SOR OUT ALARM <br /> L 3:SENSOR OUT ALARM <br /> L12:67 ANNULAR L 4:SENSOR OUT ALARM <br /> DUAL POINT HYDROSTATIC: L 5:SENSOR OUT ALARM <br /> CATEGORY : ANNULAR SPACE L 6:SENSOR OUT ALARM <br /> L10:SENSOR OUT ALARM <br /> L 1 :SHORT ALARM <br /> L :SHORT ALARM <br /> L13:87 FILL L 3:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 4:SHORT ALARM <br /> CATEGORY : PIPING SUMP L 5:SHORT ALARM <br /> L 6:SHORT ALARM <br /> L10:SHORT ALARM <br /> L14:67 STP <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY . RTD <br />
The URL can be used to link to this page
Your browser does not support the video tag.