COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SCARBOROUGH
>
2250
>
1600 - Food Program
>
PR0360602
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2021 3:24:18 PM
Creation date
4/2/2021 3:21:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0360602
PE
3611
FACILITY_ID
FA0000730
FACILITY_NAME
BROOKSIDE TERRACE COA
STREET_NUMBER
2250
Direction
S
STREET_NAME
SCARBOROUGH
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06036007
CURRENT_STATUS
01
SITE_LOCATION
2250 S SCARBOROUGH DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In: 10:45 am <br /> Time Out: 11:15 am <br /> San Joaquin County <br /> Environmental Health Department <br /> N: < <br /> _ 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)464-0138 Web:www.sigov.org/ehd <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: BROOKSIDE TERRACE COA Date: 08/12/2016 <br /> Address: 2250 S SCARBOROUGH DR, LODI 95240 <br /> Owner/Operator: BROOKSIDE TERRACE COA POOL Telephone: <br /> Program Element: 3611 -PUBLIC POOUSPA- PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #2 Pool Enclosure <br /> OBSERVATIONS:One of the post is rusted on the east part of the fence. Repair within a week. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence,portion of a building, wall, or other <br /> approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br /> 4-Inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br /> 31198) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br /> perpendicularheightof 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members shall be spaced <br /> at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br /> arc. Chain link openings shall not be larger than 1314 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br /> are allowed if the enclosure was constructed prior to July 1994. (CBC 3119B) <br /> #4 Safety Equipment <br /> OBSERVATIONS: The rope on the life ring is tangled. Untangled by today. <br /> CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br /> minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br /> rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br /> (CCR 65540) <br /> #15 Operation Records <br /> OBSERVATIONS: PH and free chlorine must be tested daily and recorded on daily log. Cyanuric acid must be tested <br /> monthly and recorded on log. Correct by today. <br /> CALCODE DESCRIPTION:Pool operatorshall test the disinfectant residual,pH, and spa water temperature a minimum of once perday. <br /> Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br /> necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br /> for at least two years and shall submit those records to the enforcement agency upon request.(CCR 65523) <br /> #27 Pool Equipment Room <br /> OBSERVATIONS:The is DE on the floor in the equipment room. Clean by today. <br /> CALCODE DESCRIPTION:Pool operator shall keep ancillary facilities well maintained.(CCR 65535)All filters, valves,pumps, strainers <br /> and equipment shall be readily accessible for repair and replacement.(CBC 31238) <br /> FA0000730 PR0360602 SCO01 08/12/2016 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.