Laserfiche WebLink
LIQUID SENSOR ALMS = 5:D I SF 3- } l•�AF' F'RESti: <br /> L 1 :FUEL ALARM CATEGORY S -4 VA PRESSURE <br /> SR0083678 <br /> L 9:DI'SP 5-6 L .':FUEL ALARNI <br /> TRI-STATE (SINGLE FLOAT) L /:FUEL ALARM <br /> C'ATEGOR'Y' : DISPENSER PAN L R:FUEL ALARM s 6:VENT CANISTES <br /> L 9:FUEL ALARM t}AT£GORY VAPOR VALVE <br /> L10:FUEL ALARM B:ATN1 <br /> L 1 :tiENSOR OUT ALARM <br /> L10:DISP 7-8 L 2:SENSOR OUT ALARM C:ATEGOR''f" ATN} F SENSOR <br /> TRI-STATE (SINGLE FLOAT) L 7:SENSOR OUT ALARM <br /> CATEGORY DISPENSER PAN L 8:S£NSOR OUT ALARM <br /> L 9:SENSOR OUT ALARM 10/22/21 QS 132 3555 W Hammer Lane Stockton CA 95209 <br /> L10:SENSOR OUT ALARM Cold Start&Functionality Testing <br /> L 1 :SHORT ALARM <br /> L 2:SHORT ALARM <br /> L 7:MHORT ALARM <br /> L 8:SHORT ALARM <br /> L 9:SHORT ALARM <br /> L10:SHORT ALARM <br /> ISD SITE ALARMS <br /> ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL EVk�ISD :) TOP <br /> ISD VAPOR LEAK FAIL <br /> PUMP SENSOR SETUP ISD VP FRES FAIL <br /> -- - - - -- - - - - - - ISD VP STATUS FAIL <br /> S 1 :87 SOUTH ISD HOSE ALARMS EVR TYPE: BALANCE <br /> TANK #; 1 ALL:FLOW COLLECT FAIL <br /> DISPENSE MODE: BALANCE NOZZLE TYPE <br /> MANIFOLDED: ALTERNATE R 3:PRE UNL VST <br /> ACTIVE SWITCHOVER: TYPE: <br /> ENABLED: NO STANDARD VAPOR PROCESSOR TYPE <br /> NORMALLY CLOSED VEEDER-ROOT POLISHER <br /> TANK #: 3 ANALYSIS TIMES <br /> TIME: 10:00 AM <br /> IN-TANK ALARMS DELAY MINUTES: I <br /> T 3:PROBE OUT <br /> LIQUID SENSOR ALM:, ACCEPT HIGH ORVR: <br /> L 3:FUEL ALARM ENABLED <br /> L ?!FUEL ALARM ISD HOSE TABLE <br /> OUTPUT RELAY SETUP L 8:FUEL ALARM <br /> - - - - - - - - - - - - L 9:FUEL ALARM ID FP FL HL 6A RR <br /> L10:FUEL ALARM 01 01 -01 02 O1 -03 <br /> R 1 :87 S L 3:SENS7R OUT ALARM <br /> TYPE: L 7:SENSOR OUT ALARM 02 02 02 0? 01 03 <br /> PUMP CONTROL OUTPUT L 8:SENSOR OUT ALARM 03 03 03 02 02 03 <br /> TANK #: I L 9:SENSOR OUT ALARM 04 04 04 02 02 03 <br /> L10:SENSOR OUT ALARM 05 05 05 02 03 03 <br /> L 3:SHORT ALARM 06 06 06 02 03 03 <br /> LIQUID SENSOR ALMS L 7:SHORT ALARM 07 07 07 02 04 03 <br /> L 1 :FUEL ALARM L 8:SHORT ALARM 06 08 08 02 04 03 <br /> L 2:FUEL ALARM L 9:SHORT ALARM <br /> L 7:FUEL ALARM L10:SHORT ALARM <br /> L 8:FUEL ALARM ISD AIRFLOW METER MAP <br /> L 9:FUEL ALARM ISD SITE ALARMS ID SERIAL NUM LABEL <br /> L10:FUEL ALARM ISD GROSS PRES FAIL ---------------------`-- <br /> L 1 :SENSOR OUT ALARM ISD DEGRD PRES FAIL 1 31027 DISP 1-2 A — <br /> L 2:SENSOR OUT ALARM ISD VAPOR LEAK FAIL 2 20123 DISP 3-4 A <br /> L 7:SENSOR OUT ALARM ISD VP PRES FAIL 3 24977 DISP 5--6 A <br /> L 8:SENS0R OUT ALARM ISD VP STATUS FAIL 4 66292 DISP 7-6 A <br /> L 9:SENSOR OUT ALARM <br /> L 10:SE NSOR OUT ALARM ISL: HOSE ALARMS <br /> L I :SHORT ALARM ALL:FL01nl COLLECT FAIL ISD FUEL GRADE HOSE MAP <br /> L 2:SHORT ALARM 1 2 3 4 <br /> L 7:SHORT ALARM FP MHH MHH MHH MHH AA <br /> L 8:SHORT ALARM <br /> L 9:SHORT ALARM 01 201 101 001 U U 1 <br /> L I U:SHORT ALARM 02 202 102 002 U U 1 <br /> UL4 203 103 003 U U 2 <br /> ISD SITE ALARMS 04 204 104 004 U U 2 <br /> ISD GROSS PRES FAIL 05 205 105 005 U U 3 <br /> ISD DEGRD PRES FAIL 06 205 106 006 U U 3 <br /> ISD VAPOR LEAK FAIL 07 207 107 007 U U 4 <br /> ISD VP PRES FAIL 08 208 108 008 U U 4 <br /> ISD VP STATUS FAIL SMARTSENSOR SETUP <br /> - - - - - - - - - _ <br /> ISD HOSE ALARMS LABEL TABLE <br /> ALL:FLOW COLLECT FAIL 1 :DISP 1-2 AFM ------------------------ <br /> CATEGORY <br /> --W---- -----_CATEGORY AIR FLOW METER 1 : UNASSIG14ED <br /> R 2:87 N 2: BLEND3 <br /> TYPE: 2:DISP 3-4 AFM 3: REGULAR <br /> PUMP CONTROL OUTPUT CATEGORY AIR FLOW METER 4: MID GRADE <br /> TANK #: 2 5: PREMIUM <br /> s 3:DISP 5-6 AFM 6: GOLF" <br /> CATEGORY AIR FLOW METER 7: BRONZE <br /> IN-TANK ALARM: 8: SILVER <br /> T 2:PROBE OUT 4:DISP 7-8 AFM 9: BLEND2 9 of 11 <br /> CATEGORY AIR FLOW METER 10: BLEND4 <br />