Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ❑x 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10/18/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Quik stop market # 132 <br /> Business Site Address City ZIP Code <br /> 3555 W. Hammer Lane Stockton 95219 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Rey Hernandez (916) 373-1166 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 617238 8712763 5/8/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> Phase 1 EVR -CERT#0154742 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines(Specify): <br /> Used: OPW Install & Maintenance Guidelines <br /> ❑ Industry Code or Engineering Standard(Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages <br /> TANK ID: (By tank number,stored product, etc.) Gasoline = 87 Gasoline = 89 Gasoline = 91 <br /> What is the tank inside diameter?(Inches) 89 3/4" 89 3/4" 89 3/4" <br /> Is the fill piping secondarily contained? ❑x Yes ❑ No I]Yes ❑ No Z Yes ❑ No ❑Yes ❑ No <br /> Is the vent piping secondarily contained? ❑x Yes ❑ No ❑x Yes ❑ No ❑x Yes ❑ No ❑Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) OPw OPw OPw <br /> What is the overfill prevention equipment response ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ZRestricts Flow ZRestricts Flow ZRestricts Flow ❑ Restricts Flow <br /> ❑A/V Alarm ❑AN Alarm ❑AN Alarm ❑A/V Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes ❑x No ❑Yes ❑x No ❑Yes ❑x No ❑Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 80 3/8" 80 3/4" 80 1/4" <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 95% 95% 95% <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes ❑x Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No(Specify in V.) ❑ No(Specify in V.) ❑ No(Specify in V.) ❑ No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑x Pass ❑ Fail ❑x Pass Eflfaiilj ❑x Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> ON site to replace 3 spill buckets and overfill inspection. <br /> Replaced all 3 spill buckets and performed overfill inspection with passing results. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3, Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form commodates,addit' al copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AN=Audible and Visual <br />