Appliance Electrical Connection Inputs ELECTRICAL PLAN NOTES <br /> ELECTRICAL GENERAL NOTES ,. <br /> Cord and Rough-In GFCI Method To 10 SEE LIGHTING PLAN FOR CONTINUATION OF EXHAUST FAN CONNECTION. <br /> Mark Equipment Descri tion Load Type Voltage System Load Load Units Plu Rating Connection Type Height A. ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS ARE BASED ON <br /> 10002 MANAGERS COMPUTER Receptacle 120V 1 Phase 2 Wire 230.0 VA(Watts) 5-15P Receptacle 18 None INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. <br /> 10005 MUSIC PLAYER Receptacle 120V 1 Phase 2 Wire 3.0 Ams 5-15P Receptacle 18 None O PROVIDE FINAL CONNECTION TO AIR CURTAIN AND INTERLOCK WITH ASSOCIATED THE CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO <br /> ftp- <br /> 10007 INKJET PRINTER Receptacle 120V 1 Phase 2 Wire 591.0 VA(Watts) 5-15P Receptacle 18 None <br /> DOOR AND DEVICES.VERIFY SPECIFICATION WITH STARBUCKS PROJECT MANAGER ADDITIONAL EXPENSE TO THE OWNER. <br /> PRIOR TO ROUGH-IN.THE CONTRACTOR SHALL NOT EXCEED THE MOCP AND PROVIDE <br /> 10008 POS REGISTER Receptacle 120V 1 Phase 2 Wire 230.0 VA(Watts) 5-15P Receptacle 18 Breaker THE PROPER DISCONNECTING MEANSB. THE CONTRACTOR SHALL VISIT THE PROJECT SITE, REVIEW EXISTING CONDITIONS <br /> 10010 DT ORDER MONITOR Receptacle 120V,1 Phase,2 Wire 21.0 VA(Watts) .5-15P Receptacle 65 Breaker AGAINST THE CONTRACT DOCUMENTS,AND FAMILIARIZE HIMSELF WITH THE WORK <br /> 10012 DIT COMM SYSTEM Receptacle 120V,1 Phase,2 Wire 2.5 Ams 5-15P Receptacle 96 Breaker O PROVIDE FINAL CONNECTION TO SIGNAGE. COORDINATE LOCATION AND ALL PRIOR TO BIDDING AND START OF THE WORK. BY SIGNING THE CONTRACT,THE <br /> 10014 POS PRINTER Receptacle 120V 1 Phase 2 Wire 1.8 Ams 5-15P Receptacle 26 Breaker REQUIREMENTS WITH SIGN CONTRACTOR PRIOR TO ROUGH-IN. PROVIDE AN CONTRACTOR ACKNOWLEDGES THE SITE VISIT HAS BEEN COMPLETED AND THE <br /> 10022 MONEY COUNTER Receptacle 120V,1 Phase,2 Wire 2.5 Ams 5-15P Receptacle 18 None APPROPRIATE LOCAL DISCONNECTING MEANS MOUNTED IN AN ACCESSIBLE, EXISTING CONDITIONS ARE ACCEPTED. <br /> INCONSPICUOUS LOCATION THAT IS WITHIN SIGHT OF THE SIGN. EACH SIGN <br /> 10024 SECURITY SAFE Receptacle 120V 1 Phase 2 Wire 180.0 VA(Watts) 5-15P Receptacle 18 None CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AND SEPARATE EQUIPMENT GROUNDING C. THE CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING EQUIPMENT, <br /> 10075 CUP LABELER Receptacle 120V 1 Phase 2 Wire 1.7 Ams 5-15P Receptacle 26 Breaker CONDUCTOR. DEVICES, LUMINAIRES, CONDUITS, SUPPORTS, HANGERS, ETC.THAT ARE NOT <br /> 10267 UC REFRIG Kitchen 120V 1 Phase 2 Wire 4.0 Ams 5-15P Receptacle 26 Breaker SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW ©2017 STARBUCKS COFFEE COMPANY <br /> 10312 SOFT HEAT SERVER STAND Kitchen 120V 1 Phase 2 Wire 0.8 Ams 5-15P Receptacle 26 Breaker 4O DUCT SMOKE DETECTOR AND RELAY FOR HVAC UNIT SUPPLY FAN SHUTDOWN SHALL WORK. <br /> 10746 DUAL SOFT HEAT BREWER Kitchen 208V,1 Phase,2 Wire 40.1 Ams 6-50P Receptacle 26 None BE FURNISHED BY THE ELECTRICAL CONTRACTOR FOR INSTALLATION BY THE D. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR STARBUCKS COFFEE <br /> 10808 GRINDER Kitchen 120V,1 Phase,2 Wire 13.0 Ams 5-20P Receptacle 26 Breaker MECHANICAL CONTRACTOR. DUCT SMOKE DETECTOR SHALL BE SYSTEM SENSOR ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED <br /> 10856 BREWER SERVER HEATER Kitchen 120V 1 Phase 2 Wire 0.6 Ams 5-15P Receptacle 26 Breaker #4120 OR EQUAL. THE ELECTRICAL CONTRACTOR SHALL PROVIDE 120 VOLT WIRING TO THE SOURCE OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR COMPANY <br /> 10874 HOT WATER DISPENSER Kitchen 120V,1 Phase,2 Wire 1300.0 VA(Watts) 5-15P Receptacle 26 Breaker TO THE DUCT SMOKE DETECTOR AND CONNECT TO SPARE 20 AMP, 1 POLE CIRCUIT BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR <br /> 11083 REACH IN REFRIG Kitchen 120V 1 Phase 2 Wire 10.0 Ams 5-15P Receptacle 84 Breaker BREAKER WITH HANDLE LOCK-ON ACCESSORY. THE ELECTRICAL CONTRACTOR EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED 2401 UTAH AVENUE SOUTH <br /> 12293 REFRIG REACH-IN 1 DOOR Kitchen 120V 1 Phase 2 Wire 8.5 Ams 5-15P Receptacle 84 Breaker SHALL ALSO PROVIDE A SYSTEM SENSOR#RTS2-AOS, OR EQUAL, REMOTE TEST SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2" INTO THE WALL SEATTLE,WASHINGTON 98134 <br /> 12407 OVEN Kitchen 208V 1 Phase 2 Wire 30.0 Ams 6-30P Receptacle 26 None STATION/ MULTI-SIGNALING ACCESSORY. INSTALL MULTI-SIGNALING ACCESSORY IN OR FLOOR AND THE OPENING GROUTED SMOOTH. (206)318-1575 <br /> 12508 BLENDER Kitchen 120V 1 Phase 2 Wire 15.0 Ams 5-15P Receptacle 26 Breaker A CONTINUOUSLY ATTENDED LOCATION,TO BE COORDINATED WITH THE AUTHORITY E. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIRED TO PROVIDE POWER <br /> 12618 U/C REFRIG Kitchen 120V,1 Phase,2 Wire 4.0 Ams 5-15P Receptacle 26 Breaker HAVING JURISDICTION AND OWNER PRIOR TO ROUGH-IN. DUCT SMOKE DETECTORS TO REMAINING EQUIPMENT, DEVICES,AND LUMINAIRES THAT ARE NOT BEING THESE DRAWINGS AND SPECIFICATIONS ARE <br /> 13682 REACH IN FREEZER Kitchen 120V,1 Phase,2 Wire 11.0 Ams 5-20P Receptacle 84 Breaker ASSOCIATED WITH HVAC UNITS THAT SHARE A COMMON AIR PLENUM SHALL BE REMOVED. CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> 14677 DRIVE THRU REGISTER Receptacle 120V 1 Phase 2 Wire 300.0 VA(Watts) 5-15P Receptacle 22 Breaker INTERLOCKED WITH ONE ANOTHER SUCH THAT ACTIVATION OF ANY ONE OF THE PROPERTY OF STARBUCKS CORPORATION, <br /> 14678 POS EXPEDITOR Receptacle 120V,1 Phase,2 Wire 1.5 Ams 5-15P Receptacle 22 Breaker ASSOCIATED DUCT SMOKE DETECTORS WILL SHUT DOWN SUPPLY FANS OF ALL F. ANY EXISTING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION THROUGHOUT WHICH IS THE OWNER OF THE COPYRIGHT IN <br /> HVAC UNITS SHARING THE COMMON AIR PLENUM. ALL FINAL WIRING SHALL BE BY <br /> 15186 WAREWASHER Kitchen 120/208V 1 Phase CONSTRUCTION.AUTOMATIC SMOKE DETECTORS IN THE AREA OF CONSTRUCTION THIS WORK. THEY SHALL NOT BE 3 Wire 30.5 Ams None Junction Box 0 None SHALL BE DISCONNECTED AND TEMPORARILT REPLACED WITH HEAT DETECTORS WHEN <br /> 15749 HOT WATER DISPENSER Kitchen 120V 1 Phase 2 Wire 1300.0 VA(Watts) 5-15P Receptacle 26 Breaker THE ELECTRICAL CONTRACTOR. THE SPACE IS STAFFED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPROVED REPRODUCED WHOLE OR IN PART), SHARED <br /> 16238 FOOD CASE Kitchen 208V 1 Phase 2 Wire 8.4 Ams None Junction Box 0 None FIRE SAFETY PROCEDURES OF THE OWNER AND THE LOCAL FIRE MARSHALL, BUT WITH THIRD PARTIES OR USED IN ANY MANNER <br /> 17564 RINSER SENSOR Kitchen 120V 1 Phase 2 Wire 180.0 VA(Watts) 5-15P Receptacle 26 Breaker O STUB-UP LOCATION TO COMMUNITY TABLE. SEE I-1104 FOR ADDITIONAL SHALL BE REACTIVATED WHENEVER THE SPACE IS NOT OCCUPIED BY THE ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> 18845 ICE MACHINE,AIR COOLED Kitchen 208V,1 Phase,2 Wire 1 19.1 1 Ams None I Junction Box 72 None INFORMATION. CONTRACTOR.AUTOMATIC SMOKE DETECTORS SHALL BE PROTECTED FROM DUST AND PROJECT WITHOUT THE PRIOR WRITTEN <br /> 19742 MASTRENA ESPRESSO Kitchen 208V,1 Phase,2 Wire 5950 VA(Watts) 6-50P Rece tacle 26 None DIRT ACCUMULATION BY REMOVING THE DEVICE FROM ITS BASE DURING THOSE CONSENT OF STARBUCKS CORPORATION. <br /> O PLUGMOLD MOUNTED AT COMMUNITY TABLE.VERIFY EXACT HEIGHT AND MOUNTING TIMES WHEN THE SYSTEM IS ALLOWED TO BE OUT OF OPERATION. THESE DRAWINGS AND SPECIFICATIONS ARE <br /> 20010 NITRO DISPENSER Kitchen 120V 1 Phase 2 Wire 10 Ams 5-15P Receptacle 26 Breaker LOCATION WITH OWNER PRIOR TO ROUGH-IN. INTENDED TO EXPRESS DESIGN INTENT FOR A <br /> G. WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> DESIGN,ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN <br /> CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF 25/50 SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS. COORDINATE PLENUM NOT REFLECT ACTUAL SITE CONDITIONS. <br /> CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR. LUMINAIRES THAT ARE NEITHER PARTY SHALL HAVE ANY OBLIGATION <br /> MANUFACTURED WITH A METAL HOUSING MEET THIS REQUIREMENT AND ARE NOT NOR LIABILITY TO THE OTHER(EXCEPT STATED <br /> REQUIRED TO BE PLENUM RATED UNLESS INDICATED OTHERWISE. ABOVE)UNTIL A WRITTEN AGREEMENT IS <br /> COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITHIN ANY MILLWORK FULLY EXECUTED BY BOTH PARTIES. <br /> WITH MILLWORK VENDOR PRIOR TO ROUGH-IN. <br /> H. COORDINATE ALL DEVICE LOCATIONS AND CIRCUIT ROUTING WITH ANY MILLWORK ARCHITECT OF RECORD <br /> WITH MILLWORK VENDOR PRIOR TO ROUGH-IN. mcg architecture <br /> I. COORDINATE THE CONNECTIONS OF ALL EQUIPMENT PROVIDED BY OTHERS WITH THE L <br /> CONTRACTOR PROVIDING THE EQUIPMENT PRIOR TO ROUGH-IN. THIS INCLUDES, y > <br /> A-36,38,40 BUT IS NOT LIMITED TO, MECHANICAL EQUIPMENT, KITCHEN EQUIPMENT, >o <br /> 3 AUDIOVISUAL EQUIPMENT, FIRE SUPPRESSION SYSTEM EQUIPMENT, FIRE ALARM � <br /> EQUIPMENT, ETC. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE <br /> Cz <br /> J 36 THE APPROPRIATE DISCONNECTING MEANS FOR,AND TO MAKE THE FINAL <br /> � �� <br /> _ CONNECTION TO,ANY HARDWIRED EQUIPMENT. THE ELECTRICAL CONTRACTOR IS <br /> ALSO RESPONSIBLE TO PROVIDE AN APPROPRIATE CORD AND PLUG FOR ANY 111 Pacifica,Suite 280,Irvine,CA 92618 <br /> CORD-AND-PLUG CONNECTED EQUIPMENT THAT IS NOT EQUIPPED WITH AN INTEGRAL <br /> A-13 P:949.553.1117 F:949.474.7056 <br /> CORD AND PLUG. <br /> J. SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THAT ARE TO BE ROUTED ENGINEER STAMP oFEss <br /> EXISTING MAIN THROUGH CONTACTORS OR RELAYS FOR CONTROL. PR oNq <br /> SWlTCH80ARD iIISB" K. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PRESERVING THE FIRE RATING ��,� �y ROY Sc'S,�.` Fti <br /> OF ANY FIRE-RATED CEILING ASSEMBLIES BY PROVIDING THE APPROPRIATE <br /> FIRE-RATED LUMINAIRE TENTS AS MANUFACTURED BY TENANT OR NELSON FIRESTOP ren Z <br /> ca Co No 46 r m <br /> ......... .. ....... . <br /> OR BY BUILDING FIRE-RATED ENCLOSURES AROUND EACH LUMINAIRE THAT IS ,,, E1 31 1,7 <br /> +$4 + 4 J +72 +84 22 20 » +84" <br /> - - <br /> 24 <br /> 84 <br /> 8 RECESSED INTO THE FIRE RATED ASSEMBLY. COORDINATE FIRE RATED CEILING <br /> 38 * - *2 <br /> A 12 <br /> ASSEMBLY LOCATIONS WITH THE ARCHITECTURAL DRAWINGS. <br /> +90 <br /> +9Q <br /> F CP � <br /> E 13682 E 13682 L. ALL EQUIPMENT, DEVICES AND LUMINAIRES SHALL BE SUITABLE FOR THE CTR <br /> Km <br /> E 18845 q <br /> B-34 Q T <br /> . .. .. .. E 11083 <br /> 3 <br /> F <br /> ENVIRONMENT IN WHICH THEY ARE INSTALLED. EQUIPMENT MOUNTED OUTDOORS Fo <br /> OF SHALL BE NEMA 3R. DEVICES MOUNTED IN DAMP OR WET LOCATIONS SHALL BE \ <br /> —20,22,24, <br /> - t'#� �#12,#1O� <br /> 4 ---------------------------------------------- <br /> EQUIPPED Date. 01/24/2020 <br /> 8-10 <br /> WEATHERPROOF. RECEPTACLESRATED 15 R 20 AMP AND 120 VOLTS WHICH ARE <br /> EX. RTU-3. 4 EX. RTU-2 I WITH A SUI"ABLE WEATHERPROOFOCOVERPLATE WHILE-RING USE I WET <br /> D <br /> D I <br /> LOCATIONS). <br /> ( <br /> M. ALL LUGS TERMINALS ETC. IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE <br /> Q <br /> B-30 <br /> { LISTED FOR A MINIMUM OF 75 DEGREE C CONDUCTORS. TERMINATIONS LISTED <br /> 1wmw <br /> FOR ONLY 60 DEGREE C CONDUCTORS ARE NOT PERMITTED. <br /> f <br /> 40 ...... N. BRANCH CIRCUITS RATED AT 20 AMPS AT 120 VOLTS THAT ARE LONGER THAN 75 <br /> FEET SHALL BE#10 AWG MINIMUM TO OFFSET VOLTAGE DROP. <br /> SR <br /> 2 <br /> ...................................... <br /> MEMO <br /> 0. BRANCH CIRCUITS RATED AT 20 AMPS AT 120 VOLTS THAT ARE LONGER THAN 150 <br /> -------------------------------------------------------- <br /> FEET SHALL BE#8 AWG MINIMUM TO OFFSET VOLTAGE DROP <br /> Q � � <br /> 1 -----= P. BRANCH CIRCUITS RATED AT 20 AMPS AT 277 VOLTAS THAT ARE LONGER THAN 150 N <br /> .. FEES SHALL BE#10 AWG MINIMUM TO OFFSET VOLTAGE DROP. <br /> -110 <br /> N A-33,37, Q. CONDUCTORS#12 AWG AND SMALLER SHALL BE SOLID. CONDUCTORS#10 AWG AND <br /> 4 EX. RTU-1 �#8#12� LARGER ARE PERMITED TO BE STRANDED. <br /> 3 W W <br /> D \ R. NO PIPING, DUCTS, OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT TO BE � U <br /> W/TH B 10 p 1087 LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. ., <br /> W <br /> 37 0 <br /> D <br /> _y <br /> 26» <br /> 33 Q <br /> 2 � 2 z Q U A <br /> ... <br /> w w <br /> - U <br /> G <br /> TlN„ „ 00 <br /> - PANEL ,4 <br /> 15186 '4 1 � � � C� <br /> 3 11 = A 10007 PAN EXIS TING — <br /> J A EL „B" <br /> A 10022 I STORE #: TBD <br /> __ I B-3s PROJECT#: 85426-001 <br /> —Z9,11 <br /> 1 I - CASEWORK CONCEPT: CORE <br /> X. EF-1 <br /> ISSUE DATE: <br /> 9 I PROGRAM MANAGER: <br /> SR 7 DESIGNER: LEVINS <br /> STORE DES S B <br /> 6 6, B_22 LEED®AP: N/A <br /> J O SR B-2 <br /> CHECKED BY: <br /> B 28 9 MCG PROJECT#: <br /> 19236 <br /> ---------------------------------- <br /> ______ <br /> . ____ _______ _ . .____ __ .__ ____ C. LEE <br /> f <br /> MCG PROJ MANAGER <br /> .................. <br /> 5 5 +60» MCG PROJ. SPECIALIST: <br /> .. B-32 <br /> 2 : <br /> _ ... <br /> SR <br /> SR RevisionSchedule <br /> Rev Date By Description <br /> 3 <br /> 3 <br /> SHEET TITLE: <br /> POWER AND <br /> dD <br /> SYSTEMS PLAN <br /> LEGENDSchnackelSCALE:AS SHOWN <br /> ����� <br /> peNiSHEET NUMBER: <br /> nem, <br /> OWER AND SYSTEMS PLAN EX/ST/NG , „Y�aamhemLwr4ow a ono <br /> ScNwuhnadaeU m <br /> NEW TO EX/ST/NG CONNECT/ON 80 South Lake Avenue, Suite 640 Pasadena, CA 91101 E-1 101 <br /> SE J09Q: 190728 <br />