Laserfiche WebLink
Commercial Gas High Efficiency Water Heater <br /> el' Series® Models Meet or exceed ASH RAE 90.1b(current standard)C.E.C.Listed <br /> NATURAL GAS AND LIQUID PROPANE GAS <br /> Model Capacity Input GPH Recovery TJ92.O57 <br /> J286020'/00"t <br /> C D E F G H Water Gas Relief Approx. <br /> Number at Degree Rise' or loor Floor Floor Floor Fluorto Floor Conn. Conn. Valve Shipping <br /> o Hot to Cold to to Air to Dia. Dia. Open Weigh] <br /> Nat. LP ofater Water Gas Vent Intake T&P <br /> U.S. Imp. BTU/Hr. BTU/Hr. ternn. Conn. Conn. Conn. Conn. Conn. <br /> Gal. Gal. Input Input 401 1001 1401 . in. in. in. in. in. in. in. in. in, lbs. <br /> EF-60T-125E-3N(A) 60 50 125,000 125,DDO 364 145 104 7 +/, 122, 6342 5 52,12 40 11/2 3/4 2/4 570 <br /> EF-60T-150E-3N A 60 50 150,000 150,000 423 169 121 7 42 124e 5342 5 524, 40 14, s, s/4 570 <br /> EF-60T-199E-3N(A) 60 50 199,999 199,999 558 223 159 7 242 121A 5342 5 5242 40 Vh sA s, 570 <br /> EF-100T-150E-3N A 100 83 150,000 150,000 450 180 129 5, 21h 12r/e 742/4 5 73,1a 60 Ph sA s/4 900 <br /> EFAGOT-199E-3NA 100 83 199,999 199,999 597 239 171 s7e 242 121/s 74s/4 5 73Ve 60 11/2 s/4 V4 900 <br /> EF-t00T-250E-3N(A 100 83 250,000 250,000 735 294 210 e/e 24z 124e 7424 5 731/e 60 142 ad 1 900 <br /> EF-100T-300E-3N A 100 83 300,000 300,000 836 335 239 92.0 77% 28114 6242 12% 700 5 7311v 60 14x s/4 1 1 900 <br /> EF-1 OOT-399E-3N(A) 1 100 83 1 399,999 399,999 1127 451 322 1 94.0 1 775Ae 1 281, 1 63 1 13 1 7411, 1 5 1 731/4 1 60 1112 1 1 950 <br /> Novel Capacity Input LPH Recovery Therm. A B C 0 E F G H Water Gas Relief Approx. <br /> Number at Degree Rise' EN. Floor Jacket Flour Floor Floor Floor Floor to Floor Conn. Conn. Valve Shipping <br /> to Dia. to Hot to Cold to to Air to Dia. Dia. Open Weight <br /> Nal. LP Top of Water Water Gas Veit TSP <br /> kW/Hr. kW/Hr. Heater Conn. Conn. Conn. Conn. Cann. Cann. <br /> Liters Input Input 22% 56'0 78'C % mm. mm, mm. mm. mm. mm. mm. mm. mm. mm, mm. its. <br /> EF-60T-125E-3N(A) 227 36.6 36.6 1378 549 394 96.0 1448 718 1087 327 1359 127 1334 1016 38 19 19 259 <br /> EF-60T-150E-3N A 227 43.9 43.9 1601 640 458 93.0 1448 718 1087 327 1359 127 1334 1016 38 19 19 259 <br /> EF-60T-199E-3N(A) 227 58.6 58.6 2112 844 602 92.0 1448 718 1087 327 1359 127 1334 1016 38 19 19 259 <br /> EF-100T-150E-3N A 379 43.9 43.9 1703 681 488 99.1 1972 718 1588 327 1899 127 1857 1524 38 19 19 408 <br /> EF-LOOT-199E-3N(A 379 58.6 58.6 2260 905 647 98.5 1972 718 1588 327 1899 127 1857 1524 38 19 19 408 <br /> EF-100T-250E-3N(A 379 73.2 73.2 2782 1113 795 97.0 1972 718 1588 327 1899 127 1857 1524 38 19 25 408 <br /> EF -300E-3N(A) 379 87.9 87.9 3165 1268 905 1 92.0 1 1972 1 718 1 1588 1 327 1899 127 1857 1524 38 19 25 408 <br /> EF-t00T-399E-3N(A) 1 379 1 117.2 117.2 4266 1707 1219 1 94.0 1 1972 1 718 1 1600 1 330 1861 127 1857 1524 38 25 25 431 <br /> For propane gas models change wi8x"N"to"X°end remove"E"from the model number. Note:The weight is the same for both ASME and Non-ASME models. <br /> Exempt:EF-1007-150-3X All models comply with the latest ultra-Icw NOx requirements of 14 ng/J or lass. <br /> a)d ltmmbec <br /> available models nuME construction. To unfair ABME construction <br /> dthe(A)tothe end of model Amp Draw range=1.0 to 1.8 amps. <br /> Example: EF-60T-125E-3NA 14.0'w.c,maximum static,4.5'w.c.minimum running(recommend 7.0'w.o. <br /> minimum running) <br /> GASINLEF <br /> t&P&h' EXHAUST <br /> AIR INTAKE <br /> I <br /> ALVE <br /> 3*PVC INLET r/,'NPT GAS INLET <br /> h. B <br /> ■ r � ■ <br /> 1+/d NPT OUTLET - <br /> O <br /> A 1'NPT SPACE E <br /> HEATING OUTLET <br /> CLEANOUT H 1'NPT SPACE C' <br /> C HEATING RETURN <br /> D P/i NPT INLEF <br /> F <br /> s/:O.D.J 242'MIN. 31 PVC EXHAUST ' <br /> Noe:Diagrams arefor both 60 and 100 gallon models. <br />