Laserfiche WebLink
2,0901.1g/L, and 8,590 p.g/L, respectively. Further information is available in IT Corporation's <br />July 29, 1999, Underground Storage Tank Removal and Over-excavation Report. <br />October 2009 Pilot Sparge Test by Stantec Consulting Corporation <br />On October 6, 2009, Stantec injected approximately 26.8 pounds of oxygen into each remediation well <br />and recorded depth to water, induced vacuum, and vapor concentration measurements in other site wells <br />to determine an approximate radius of influence associated with the injections. The pilot sparge test <br />demonstrated strong lateral and vertical communication between the B and B Zones when injecting into <br />the B Zone. Further information of well installations and the pilot sparge test are available in Stantec's <br />November 10, 2009, Remedial Well Installation and Sparge Test Report. <br />March 2010 through June 2012 Oxygen Sparging Events by Stantec <br />From March 2010 through June 2012, Stantec conducted bi-weekly oxygen injection events in wells OS- <br />23 through OS-28. Approximately 13.4 pounds of oxygen was injected into each well and dissolved <br />oxygen, depth to water, induced pressure, and vapor concentration measurements were recorded. At the <br />completion of bi-weekly injection events, approximately 59 pounds of TPHg had been destroyed. Further <br />information of site activities is available in Stantec's Semi-annual Summary Reports. <br />GHD I Well Installation Work Plan Addendum 1 Attachment B111193145 (05)1 Page 6