Laserfiche WebLink
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT <br /> 00 <br /> ROOFTOP UNIT SCHEDULE AIR DEVICE SCHEDULEC>, O� <br /> HVAC NOTES Lo Lo z <br /> *'o <br /> COOLING CAPACITY FRAME <br /> SUPPLY FAN �1 (MBH) HEATING ELECTRICAL DATA MARK SERVICE MANUFACTURER MODEL STYLE FACE SIZE NECK SIZE TYPE NOTES 1. NOTES APPLY TO ALL MECHANICAL SHEETS. Q <br /> NOMINAL E.S.P. OSA INPUT 2. EACH CONTRACTOR IS RESPONSIBLE FOR HAVING S <br /> THOROUGH KNOWLEDGE OF ALL DRAWINGS AND 0, � ` <br /> MARK MANUFACTURER MODEL TONS CFM (IN. WC) (CFM) TOTAL SENSIBLE SEER\EER (MBH) V/PH MCA MOCP WEIGHT CD1 SUPPLY METAL*AIRE 5700-6 AL ROUND NECK CEILING DIFFUSER 24 X 24 PER PLAN LAY-IN A, B, C, D SPECIFICATIONS AS THEY RELATE TO THIS WORK. NO <br /> ADDITIONAL COMPENSATION SHALL BE ALLOWED DUE TO tj W) Lo <br /> m <br /> RTU-1 CARRIER 48HC-A06 1 5 1 2000 1 0.5" 1 784 1 60 1 48 1 15.2 1 82 208/3 1 29 40 799 1 LACK OF THIS KNOWLEDGE. .. Lu <br /> Q <br /> NOTES (ALL NEW UNITS): 3. PROVIDE ALL MATERIALS FOR A COMPLETE U a <br /> A. PROVIDE FILTER WITH EACH UNIT. RG1 RETURN METAL*AIRE CC5-6 EGGCRATE CEILING RETURN GRILLE 24 X 24 PER PLAN LAY-IN A, B, C, D LL <br /> INSTALLATION IN ALL RESPECTS READY FOR INTENDED LL LL <br /> B. PROVIDE WITH FULLY MODULATING ECONOMIZER WITH ENTHALPY CONTROL. USE AND IN STRICT ACCORDANCE WITH STATE AND LOCAL O O <br /> C. SMOKE DETECTORS TO BE PROVIDED AND INSTALLED BY CARRIER. LOCATE AS SHOWN ON PLAN. CODES AND MANUFACTURER'S RECOMMENDATIONS. <br /> D. CONDENSATE TRAP SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR. PROVIDE TRAP OF ADEQUATE DEPTH TO PREVENT GENERAL INFORMATION (ALL DEVICES): r <br /> STATIC FROM OVERCOMING TRAP SEAL. ROUTE TO NEAREST APPROVED RECEPTOR. 1. ALL DIFFUSERS ARE 4-WAY THROW UNLESS NOTED OTHERWISE. 4. SPRINKLER HEAD AND LIGHTING FIXTURE LOCATIONS v <br /> E. PROVIDE WITH STANDARD ROOF CURB AND ACCESSORIES. 2. ALL AIR DEVICES SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. FOR TAKE PRECEDENCE OVER DIFFUSER LOCATIONS. <br /> F. OUTDOOR AMBIENT DESIGN TEMPERATURE 95 DEG.F. COORDINATE WITH ELECTRICAL CONTRACTOR AND FIRE <br /> G. SET FAN OPERATION TO CONTINUOUS. PROTECTION CONTRACTOR. 9 Z <br /> H. TEMPERATURE SET POINTS DURING OCCUPIED HOURS; HEATING MODE: 66°F - COOLING MODE: 75°F. NOTES: <br /> A. DIFFUSER NECK SIZE SHALL BE SAME AS BRANCH DUCT SIZE UNLESS NOTED OTHERWISE. 5. DUCTWORK IDENTIFICATION AND INSTALLATION TO O <br /> B. DAMPER AT TAKEOFF TO DEVICE. ADHERE TO GOVERNING CODES. LL <br /> C. STANDARD OFF-WHITE FINISH. H o') <br /> U <br /> D. PROVIDE NECK FOR DUCT CONNECTION. 6. DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS (`7 <br /> AND REPRESENTATIVE OF THE INSIDE EQUIVALENT FREE h 0. <br /> EXHAUST FAN SCHEDULE AREA REQUIRED TO MAINTAIN THE AIR FLOW SPECIFIED. Z <br /> MARK QUANTITY MANUFACTURER M DEL FM E.E.S.P. IN. W V Ph WATT CONTROL IF DUCT LINING IS REQUIRED, INCREASE DUCT SIZE TO ', Q Z <br /> QO C S ( C) / S CO O MAINTAIN ORIGINAL INSIDE DIMENSIONS. IF DUCT SIZES ® W Z <br /> EF-1 1 GREENHECK SP-6150 100 0.25" 120/1 129 LIGHT SWITCH NEED TO BE ALTERED FOR SPACE REQUIREMENTS, > OC <br /> ENSURE THE ORIGINAL INSIDE DUCT EQUIVALENT FREE Q O (/) <br /> NOTES: AREA IS MAINTAINED. W <br /> A. PROVIDE GRAVITY BACKDRAFT DAMPER. Ex J <br /> B. PROVIDE SPRING VIBRATION ISOLATORS FOR HANGER ROD SUPPORTS. 7. TYPICAL BRANCH DUCT FITTING DETAIL IS APPLICABLE <br /> C. THROUGHOUT. FLEXIBLE DUCTWORK IS ONLY PERMITTED W <br /> 0 (� r^ <br /> FOR FINAL CONNECTION - MAX LENGTH OF 51-0...,l if Z <br /> 8. FURNISH AND INSTALL VOLUME/BALANCE DAMPERS AT Z <br /> Z OSA CALCULATIONS ALL BRANCH DUCTS TO DIFFUSERS. LOCATE DAMPERS AO 0 Z <br /> MINIMUM 4'-0"AWAY FROM DIFFUSERS. PROVIDE ACCESS <br /> CLASSIFICATION AREA CFM PER PEOPLE CFM PER ZONE AS REQUIRED. Lo <br /> FT2 AREA FT2 PERSONS PERSON EFFECTIVENESS a <br /> 9. ALL CEILING DIFFUSERS ARE 4-WAY PATTERN UNLESS <br /> (AZ) (Ra) (PZ) (Rp) (EZ) SHOWN OTHERWISE. <br /> ICE CREAM SHOP/RESTAURANT 1538 0.18 49 7.5 0.8 10. PROVIDE A COMPLETE TEST AND BALANCE FOR HVAC <br /> SYSTEM. AIR BALANCE SHALL BE WITHIN 5% OF <br /> Vbz R PZ+ RaAZ VoZ Vb)E Z 715.93 SCHEDULED AIRFLOWS. PROVIDE A COPY TO THE OWNER <br /> P TOTAL REQUIRED: <br /> AND ENGINEER. <br /> 7.5*49+0.18*1538 =644.34 644.34/0.8 = 715.93 TOTAL SUPPLIED: 784 USED AR <br /> 11. INSTALL VTR'S AND EXHAUST FANS A MINIMUM OF 10 FT GF, lF <br /> FROM OUTSIDE AIR INTAKE. <br /> -1658 <br /> MECHANICAL <br /> MECHANICAL SYMBOLS REN: 10/29/21�P <br /> 9TF <br /> OF CALF <br /> H ROUTE 8" EXHAUST DUCT 18/12 RECTANGULAR DUCT 18"WIDE <br /> U UP THRU ROOF WITH ROOF BY 12" DEEP (INSIDE CLEAR DIMENSIONS) ;13 <br /> CAP AND INSECT SCREEN 0 <br /> O (E) EXT. LADDER TO ROOF 12" DIAMETER ROUND DUCT C <br /> w 12 (INSIDE CLEAR DIMENSIONS) 0 <br /> a m <br /> o <br /> ZSUPPLY DUCT IN SECTION co <br /> O <br /> EF-1 LTG. LTG. LTG. <br /> Q D <br /> 100 CFM CD3 <br /> U 50 CFM CD2 RETURN OR EXHAUST DUCT IN SECTION D <br /> s 400 10"o s 400 LTG. <br /> C <br /> w CFM CFM I <br /> Y u ELBOW WITH TURNING VANES C <br /> U) 10"o cn <br /> W 7s <br /> p TEE WITH TURNING VANES <br /> O m <br /> LTG. LTG. rm/x LTG. C <br /> Q RTU-1 16°� ROUND (OR OVAL) ELBOW D <br /> Q LTG. T LTG. i <br /> SUPPLY AIR DIFFUSER WITH Z <br /> m p 14"o RGI RETUR 12"o ROUND SUPPLY DUCT D <br /> p LTG. 00 CFM r <br /> V L 16"o RETURN OR EXHAUST AIR DIFFUSER -0 <br /> WITH ROUND DUCT O <br /> p 12"o LTG. LTG. 10"o LTG. p <br /> O CID <br /> 400 CFM DIFFUSER OR GRILLE TYPE &CFM 0 <br /> CD2 10"o <br /> CFM 10"o - 10"o O THERMOSTAT <br /> r/A <br /> CD2 CD2 <br /> s s s 400 - s 400 O SPACE TEMP. SENSOR <br /> CFM CFM <br /> RETUR 3550 RETUR <br /> LTG. LTG. CFM LTG. LTG. LTG. LTG. S H C SPACE TEMP. /HUMIDITY/CO2 COMBO SENSOR <br /> RG1 <br /> DO SMOKE DETECTOR M <br /> 600 CFM 700 CFM <br /> 16"o 16"o J <br /> - BALANCE DAMPER <br /> • <br /> � Z m <br /> MECHANICAL PLAN 1/4" = 1'-0" a <br /> O � <br /> I. SUPPORT DUCT WITH 1-1/2' x 26 GA. • <br /> I. AIR CONDITIONING UNIT. GALVANIZED S/M STRAPS s 4'-0' �+ Z <br /> 2. 3/8' ?X 3' LAG BOLT WITH INTERVALS,SECURE TO STRUCTURE ABV. S <br /> 1 WASHER BEHIND HEAD.(2)ON DUCT INSTALLED PER CMC CHAPTER 6 GYPSUM BD.CEILING,SEE ARCH.DRAWINGS. , , 2 <br /> TWO TWO SIDES. AND SMACNA HVAC DUCT CONSTRUCTIONS I. ROUND GALVANIZED BHT.MTL.DUCT SQUARE TO ROUND GALVANIZED SHEET00 <br /> 3. 2' x 1/4' CONTINUOUB DENSE STDS. THRU ROOF,SEE MECHANICAL PLAN <br /> NEOPRENE SPONGE GASKET. 2. INSULATED FLEXIBLE AIR DUCT WITH(FULL FOR SIZE. METAL TRANSITION. . O <br /> 2 4. GALVANIZED S/M FLASHING. 150% RADIUS).SEE MECHANICAL PLAN FOR 2. ROUND GALVANIZED BHT.MTL.907 MOLDED WHITE PLASTIC GRILLE FURNISHED <br /> 5. ROOF CURB. ELBOW. `- <br /> NO.8 GAGE GALV.STEEL WIRE SIZE. WITH EXHAUST FAN. <br /> I�■� <br /> 3 6. ROOFING FELTS. 3. START COLLAR,FUW1614ED WITH DUCT 3. 2x WOOD FRAMING OR BLOCKING. GRILLE BUTTON FURNISHED WITH FAN. <br /> I3 1. CANT STRIP. 4. GALVANIZED S/M SQUARE t0 ROUND BOX 4. lx1/2' SHEET METAL SCREWS MIN.4' CEILING MOUNTED EXHAUST FAN. <br /> IF APPLICABLE,SEE MECH.PLAN 1/4'? x 1-1/2" LAG SCREW INTO WOOD FRAMING <br /> 8. 8. 1-I/2 RIGID INSULATION f O.C.,TAPE WITH 2 HARDCABT TAPE. <br /> 5 4 COMPATIBLE WITH ROOFING. 5. ACOUSTICAL LAY-IN T-BAR CEILING,SEE 5. INTEGRAL BACKDRAFT DAMPER OR BLOCKING. q/1/20 <br /> 9. 2X WOOD LEVELING BLOCK ARCCAL LAY-INTRUAL DRAWINGS. ADJUSTABLE MOUNTING FLANGE ON EACH <br /> 6 SHAPED TO MATCH ROOF SLOPE. 1. TYPICAL /M SC DIFFUSER SIDE,FURNISHED WITH EXHAUST FAN. <br /> 10. FINISH ROOF, 1. +"1 x 1R' S/M SOWS,(4' O.C.MIN.)TAPE w/ <br /> G)_ <br /> 2'MASTIC CAPE. I�- 4 <br /> II. 4 x 6 BLOCKING. <br /> 12. 3/8'? LAG SCREW THRU STRUCTURE 1 8. SUPPORT DIFFUSER WITH(4)I-IR' x 26 GA. <br /> GALVANIZED S/M STRAPS,SECURE TO <br /> c� ® 's 24' O.C. STRUCTURE ABOVE. 5 10 `■ i , e- <br /> 13. 5/16 10 SELF TAPPING. \_- 9. SHEET METAL SCREW,(TYPICAL). 2 <br /> SCREWNIITH 18 GAGE STRAP. f SUPPORT STRAPS PER TABLE 2 1 11 JOB NO.: <br /> Im <br /> (BY GENERAL CONTRACTOR) <br /> 3 <br /> 12 DUCT DIA. STRAPS 3 12 DRANN BY:gwr <br /> II UP TO 14' 26 GAUGE,11/21 WIDE,4'ON CENTERS 4 i i i i i i i i i i i i i nn i O <br /> SHEET NO.: � <br /> OVER 14' 26 GAUGE,11/21 WIDE,4'ON CENTERS ' ' <br /> UP TO 23' - f Q <br /> OVER 23' 22 GAUGE,11/2'WIPE,4'ON CENTERS (6 . . . O <br /> UP TO 31' <br /> LAY-IN O <br /> •A e - e N <br /> UL <br /> . ,Q ® , ® �r - _ _ _ ® ® ROOF MOUNTED EXHAUST FAN of SHEETS <br /> HVAI IUI,® �\®��" 0 FLET® -U ,;T �UPPO TD � F I I SE n IIVSTHLL. 0 ^L� i®�I� � �;; AINi 0 PENETRATION DETAIL <br /> v DATE:6/15/20 <br /> ionCIONd IVNoiivonC]3 NS3cioin d NV AS 43on0O 1d <br />