My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORADA
>
4219
>
2300 - Underground Storage Tank Program
>
PR0524617
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 4:08:14 PM
Creation date
4/14/2021 10:30:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0524617
PE
2351
FACILITY_ID
FA0016523
FACILITY_NAME
AISLE 1 #2356
STREET_NUMBER
4219
Direction
E
STREET_NAME
MORADA
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12429017
CURRENT_STATUS
01
SITE_LOCATION
4219 E MORADA LN
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Environmental Reporting System (CERS) Underground Storage Tank � Monitoring Plan <br /> Facility/Site <br /> Aisle l #2356 LIST Tank #/CERS Tank CERS ID <br /> ID # 10185183 <br /> 219 E MORADA LN TA0515787 / <br /> 10185183-003 <br /> TOCKTON , CA 95212 Tank Info: Installed Date: 2/1/200712 :00:00 AM - Tani( Use: Motor Vehicle Fueling - Tank <br /> Contents: Regular Unleaded - Type Of Tank: Double Wall - Piping Construction : Double- <br /> walled <br /> Pipe Monitoring is Performed Using the Following Method (s) <br /> Yes Continuous Monitoring of Piping Secondary Containment <br /> Piping Secondary Containment Panel Manufacturer Leak Sensor Manufacturer <br /> Liquid Veeder Root Veeder Root <br /> Panel Model # Leak Sensor Model # <br /> TLS 350R 330020-463) 794380-304, 794380-208 <br /> Yes Leak Alarm Triggers Automatic Pump Shutdown <br /> Yes Failure/Disconnect Triggers Pump Shutdown <br /> Mechanical Line Leak Detector Performs 3 GPH Leak Test <br /> MLLD Manufacturer MLLD Model <br /> Yes Electronic Line Leak Detector Performs 3 GPH Leak Test <br /> ELLD Manufacturer ELLD Programmed In-Line Testing ELLD Triggers Automatic Pump Shutdown <br /> eederRoot Yes <br /> ELLD Model ELLD Failure/Disconnect Triggers Automatic Shutdown <br /> 48480 Yes <br /> Pipeline Integrity Testing Visual Pipeline Monitoring <br /> Pipeline Integrity Testing Frequency Visual Pipeline Monitoring Frequency <br /> ther <br /> Continuous <br /> Suction Piping Meets Exemption Criteria <br /> No Regulated Piping Per Health and Safety Code, Division 20, Chapter 6.7 Is Connected To The Tank System <br /> Other Pipeline Monitoring <br /> Under Dispenser Containment ( UDC) Monitoring <br /> DC Monitoring Detection of Leak into UDC Triggers Audible and Visual Alarms <br /> ontinuous Yes <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown <br /> DC Panel Manufacturer Yes <br /> eeder Root Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br /> DC Panel Model # Yes <br /> LS-350R UDC Monitoring Stops Flow of Product at Dispenser <br /> DC Leak Sensor Manufacturer <br /> eeder Root UDC Construction <br /> DC Leak Sensor Model Double-walled <br /> 94380-208, 794380-304 UDC Secondary Containment Monitoring <br /> Liquid <br /> Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br /> Yes <br /> Periodic System Testing <br /> ELD Testing <br /> Secondary Containment Testing <br /> Yes Spill Bucket Testing <br /> Printed on 1/8/20214 :40 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.