COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2021 11:03:57 AM
Creation date
4/19/2021 9:07:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> 16. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) REGULAR PREMIUM DIESEL <br /> Are both vent and tank riser piping 0 Yes 0 Yes 0 Yes 0 Yes <br /> secondarily contained? C9 No M No Z No 0 No <br /> OPE Model 0 N.71 SO OPW71SO <br /> What is the OPE response when activated? Z Shut off Z Shut off Z Shut off 0 Shut off <br /> (Check all that apply.) Flow Flow Flow Flow <br /> 0 Restricts 0 Restricts Z Restricts 0 Restricts <br /> Flow Flow Flow Flow <br /> 0 Audible 0 Audible 0 Audible 0 Audible <br /> Alarm Alarm Alarm Alarm <br /> 0 Visual 0 Visual 0 Visual 0 Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping 0 Yes* 0 Yes* 0 Yes* 0 Yes* <br /> that may interfere with the OPE operation? Z No Z No 0 No 0 No <br /> At what level in the tank is the OPE set to 83.76" 83.75" 83.75" <br /> activate? (Inches from bottom of tank) <br /> What is the percent capacity of the tank at 95% 95% 96% <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to Z Yes 0 Yes Z Yes 0 Yes <br /> respond when the stored substance 0 No 0 No 0 No 0 No <br /> reaches the designated regulatory level? <br /> 17. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results Z Pass N Pass Z Pass 0 Pass <br /> 0 Fail 0 Fail 0 Fail 0 Fail <br /> 18. COMMENTS <br /> Describe all results marked "Fail"and each proposed remedy. <br /> Mark here if: <br /> El Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.