My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2022 2:25:35 PM
Creation date
4/19/2021 9:17:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
131
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Overfill Prevention Equipment Inspection Report <br />6. OVERFILL PREVENTION EQUIPMENT DETAILS <br />Tank ID (one OPE per column) <br />87 Gasoline <br />© Yes <br />Clear Diesel <br />0 Yes <br />Red Diesel <br />© Yes <br />© Yes <br />Are both vent and tank riser piping <br />secondarily contained? <br />© No <br />.✓© No <br />® No <br />0 No <br />OPE Model <br />61 SO <br />61 SO <br />61 SO <br />What is the OPE response when <br />El Shut off <br />Shut off <br />© Shut off <br />57 Shut off <br />activated? <br />Flow <br />Flow <br />Flow <br />Flow <br />(Check all that apply.) <br />© Restricts <br />EI Restricts <br />© Restricts <br />0 Restricts <br />Flow <br />Flow <br />Flow <br />Flow <br />© Audible <br />© Audible <br />FM Audible <br />0 Audible <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />El Visual <br />© Visual <br />[M Visual <br />Visual <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />Are flow restrictors installed on vent piping <br />© Yes* <br />Yes* <br />Yes* <br />Yes* <br />that may interfere with the OPE operation? <br />® No <br />® No <br />® No <br />r] No <br />At what level in the tank is the OPE set to <br />83.375 <br />84.125 <br />83.875 <br />activate? Inches from bottom of tank <br />What is the percent capacity of the tank at <br />94% <br />94% <br />94% <br />which the OPE activates? <br />Is the OPE in proper operating condition to <br />Yes✓0 <br />Yes* <br />© Yes* <br />0 Yes* <br />respond when the stored substance <br />© No <br />© No <br />© No <br />0 No <br />reaches the designated regulatory level? <br />7. SUMMARY OF TESTING RESULTS <br />OPE Inspection Results <br />Pass <br />Q Fail <br />0 Pass <br />© Fail <br />0 Pass <br />0 Fail <br />® Pass <br />E Fail <br />8. COMMENTS <br />Describe all answers marked "No" or "Fail" and proposed remedy. <br />List all monitoring equipment either replaced or repaired. <br />* Mark here if: <br />® Flow restrictors interfere with overfill prevention and equipment repairs required. <br />Additional copies of this page may be attached. <br />Attach tank chart(s), measurements, calculations, and In -Tank Setup report(s) <br />Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.