Laserfiche WebLink
Monitoring Report Compliance Checklis 3 <br /> Discharges Regulated by Title 27 and/or Part 258 <br /> Reference Parameter Yes No N/A RWQCB <br /> Reviewer Comment <br /> WDRs/MRP/ Groundwater Monitoring X <br /> Standard <br /> Provisions 1. Are all groundwater Field <br /> (1993,1997,2000, Parameters Monitoring Parameter, <br /> 2003) and COCs(if required)sampled <br /> and analyzed? <br /> m. Have any groundwater X Wells MW-5 and MW-8. Eight VOCs were <br /> concentration limits been detected in well MW-5 and five VOCs were <br /> exceeded? If yes, identify in detected in well MW-8. <br /> comments. <br /> n. is there a description and X <br /> graphical presentation of <br /> groundwater flow direction and <br /> gradient? <br /> o. Monitoring Wells: Is there a X <br /> description, method,and time of <br /> water level measurement and well <br /> recovery time? <br /> p. Purging: Is there a description of X <br /> the purging method, purge pump <br /> and its placement, and field <br /> parameters? <br /> WDRs Semiannual/Annual Monitoring <br /> Standard Report(when applicable) <br /> Provisions <br /> (1993,1997,2000„ q. Are all monitoring parameters and <br /> 2003) COCl graphed so as to show <br /> historical trends at each <br /> Monitoring Point and Background <br /> Monitoring Point? <br /> r. is all monitoring analytical data <br /> obtained in the last year presented <br /> in tabular form, as well as on a <br /> diskette or CD? <br /> s. Is there a comprehensive X County has proposed to install additional <br /> discussion of the compliance LFG wells near the eastern property boundary <br /> record and the result of any to collect additional LFG in the vicinity of <br /> corrective actions? well MW-5. MSW discovered outside of <br /> footprint is likely contributing to groundwater <br /> impacts. <br />