My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2021 8:26:21 AM
Creation date
4/21/2021 9:51:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
21721070
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Owner/Operator Response <br /> 106 CCR 2632 ( d ) ( 2 ) , 2634 ( e ) Failed to have an approved UST response plan . <br /> The response plan is not current and /or not approved by the EHD . The response plan must be <br /> uploaded to the California Environmental Reporting System ( CERS ) . Immediately log into CERS, <br /> upload the completed form , and submit for review by the EHD . Ensure a copy is available for <br /> inspection at anytime . <br /> This is a minor violation . <br /> Response: Owner/Operator updated Response Plan and submitted into CERS on August 28, 2019. <br /> Response Plan accepted January 6, 2020. <br /> 121 CCR 2712 (f) Failed to submit a written response within 30 days of receiving an inspection report . <br /> An inspection was last done on 08/02/ 18 and an inspection report was issued identifying <br /> information to be submitted to bring this site into compliance . This information was required to be <br /> submitted by 09 /01/ 18 . This information was received on 09 /06/ 18 , 5 days late . An operator that <br /> receives an inspection report shall have 30 days to submit a written response that includes a <br /> statement documenting corrective actions taken or proposing corrective actions which will be <br /> taken . Ensure that a written response documenting corrective actions taken or proposed is <br /> submitted within 30 days of receiving an inspection report . <br /> This is a Class II violation . <br /> Response: Corrective action performed by California Hazardous Service, Inc. on September 13, <br /> 2018. <br /> 124 CCR 2637 . 2 ( d & e ) , 2665 ( a & b ) " Overfill Prevention Equipment Inspection Report Form " not <br /> submitted within 30 days of inspection . <br /> Overfill prevention testing was performed on 09/ 13/2018 and a test report was submitted on <br /> 10/ 23/ 18 , 10 days late . A copy of the test report must be submitted within 30 days of the tests . <br /> Take all necessary precautions to ensure testing and submittal of test reports are performed in a <br /> timely manner . <br /> This is a minor violation . <br /> Response: Corrective action performed by California Hazardous Service, Inc. on September 13, <br /> 2018. <br /> 209 CCR 2716 ( a -e ) Failure to conduct the designated UST operator visual inspection at least once every <br /> 30 days . <br /> The designated operator failed to check and note all required items on the visual inspection reports . <br /> -The inspection reports from 10/ 16/ 18 to 7/ 13 / 19 did not include the Signature and the date signed <br /> by the owner/operator . The inspection reports were not signed by the owner/operator . <br /> During the visual inspection , the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and shall check all required items on the <br /> report . Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports . <br /> This is a minor violation . <br /> Response: Updated and signed DO reports attached to the correspondence. <br />