My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2021 8:26:21 AM
Creation date
4/21/2021 9:51:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
21721070
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t• ` t ` SAN � Q Q ( N Environmental Health Department <br /> 1.. 1 ----Y C O U N T Y <br /> Clas=�� rApCreetneS5 or4ows here - <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Phone: Date : <br /> Frontier California Inc . : Manteca CO 209 239- 0258 August 13 , 2019 <br /> Facility Address: CERS ID: <br /> 430 W Center St , Manteca , CA 95336 10141507 <br /> Inspection Contact: Title: Phone: <br /> Masood Choudhury Env . Mana er 909 620 - 5962 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - O eratin Permit 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> 0 Inspection 0 Photos 0 Samples Kraig Kinder, D . O <br /> Service Technician Onsite: Exp. Date: Designated Operator: Exp. Date: <br /> Kraig Kinder 02/07/2020 Kraig Kinder 12/07/2020 <br /> Service Technician Manufacturer's Training <br /> VR , 09/24/ 19 , FFS , 04/ 17/20 , VMI , 09/24/20 <br /> CCR = Title 23 California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during <br /> File Review <br /> 101 HSC 25284 ; CCR Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees V ❑ R ❑ COS <br /> 2711 (d) <br /> 102 HSC 25284 (a) (3) (A)/(B) No written agreement between tank owner and tank operator to monitor the tank system V ❑ R ❑ COS <br /> 103 HSC 25292 . 21 25299. 30 Failure to submit and maintain complete and current financial responsibility documents V ❑ R ❑ COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current V ❑ R ❑ COS <br /> 105 CCR 2632 (d) ( 1 ) , Failed to have an approved UST monitoring plan V ❑ R ❑ COS <br /> 2634(d) <br /> 106 CCR 2632 (d) (2) , Failed to have an approved UST response plan m V ❑ R ❑ COS <br /> 2634(e) <br /> 107 CCR 2632 (d) , 2641 (h) , Plot plan/site map not submitted or failed to completely show where monitoring is performed V ❑ R ❑ COS <br /> 2711 (a) <br /> 108 CCR 2637 , 2638 (e) , Failed to notify the EHD 48 hours prior to conducting testing V ❑ R ❑ COS <br /> 2643(8) <br /> 109 CCR 2637 (a-d) , 2712 Failed to test secondary containment , or failed to maintain test records for 36 months V ❑ R ❑ COS <br /> 110 CCR 2637 (e) , 2637 (f) Failed to submit " Secondary Containment Testing Report Form" within 30 days after the test V ❑ R ❑ COS <br /> 111 CCR 2638 , 26410) , Failed to test monitoring and leak detection equipment every 12 months A V ❑ R ❑ COS <br /> 2715(f) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance V ❑ R ❑ COS <br /> 113 CCR 2638(c) , 2638 (d) Failure to submit " Monitoring System Certification Form" within 30 days of completion of the test V ❑ R ❑ COS <br /> 114 CCR 2636 (f) (3) , 2643 (c) No 0. 1 gph annual line integrity test for pressurized piping , or within 30 days after repair V ❑ R ❑ COS <br /> (3) <br /> 115 CCR 2715(a) ( 1 ) (B) , " Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days V ❑ R ❑ COS <br /> 2715(a) (3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification V ❑ R ❑ COS <br /> 117 CCR 2663 , 2712(b) (6) Failure to comply with tank lining , recordkeeping , and inspection requirements V ❑ R ❑ COS <br /> L12 <br /> CCR 2715(a) ( 1 ) (A) , Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" V ❑ R ❑ COS <br /> 2715(a) (2) <br /> HSC 25299(a) (8) , Documents were falsified or misrepresented V ❑ R ❑ COS <br /> 25299 (b) (7) <br /> CCR 2635(d) Failed to submit UST Certification of Installation/Modification V ❑ R ❑ COSCCR 2712 (f) Failed to submit a written response within 30 days of receiving an inspection report V ❑ R ❑ COS <br /> FA0003838 PR0231425 SCO01 08/13/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 1 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468- 3420 F 209 464-0138 1 www . sjcehd. com <br />
The URL can be used to link to this page
Your browser does not support the video tag.