7 In®Tank Setup Nigh Produce <br /> High Product <br /> If necessary, press STEP until you see the message : <br /> Tt : (Product Label) <br /> HIGH PRODUCT: 000% <br /> High Product warns when the volume of fluid in the tank exceeds the value you enter here . The High Product alarm <br /> occurs whenever this value is exceeded , whether or not a delivery is in progress. <br /> In U . S . installations this is especially useful in applications such as used oil holding tanks , where the rate of fill can <br /> be too gradual for the system to recognize the increase as a delivery and activate the Overfill Limit. It can trigger <br /> the same alarm indications as Overfill Limit. Set this limit at a percentage that is between the Overfill Limit <br /> percentage and 95 % (of the tank' s capacity) [see Figure 7- 1 ] . <br /> In international installations , this is especially useful to warn of an impending overfill. It can trigger the same alarm <br /> indications as Overfill Limit. Set this limit to 98% if the label volume is greater than 25 ,000 litres and to 96 % if the <br /> label volume is less than 25 , 000 litres. <br /> Press CHANGE. Enter the percent limit . Press ENTER to confirm your entry. The system displays : <br /> HIGH PRODUCT: XX% <br /> PRESS <ST € P > TO CONTINUEli <br /> Delivery Limit <br /> If necessary, press STEP until you see the message : <br /> Ti : ( Product Label) <br /> DELIVERY LIMIT: 000°1a <br /> Delivery Limit warns when the level of fluid in the tank drops to a level at which the operator calls for a delivery. Set <br /> this percentage at a volume higher than that of the Low Product alarm [see Figure 7- 11 . <br /> Press CHANGE. Enter the percent limit. Press ENTER to confirm your entry. The system displays <br /> DELIVERY LIMIT: XX% <br /> PRESS <STEP> TO CONTINUE <br /> Low Produce <br /> If necessary, press STEP until you see the message : <br /> CT1 : (Product Label) <br /> LOW PRODUCT: 000000 <br /> Low Product warns when volume in a tank recedes to the level you enter here [ser.% Figure 713 , <br /> In international installations , assuming no water in the tank , this limit should be set no lower than : the tank volume <br /> at 250 mm for Mag probe types 8473 , or the tank volume at 125 mm for Mag probe types B493 (these are the <br /> minimum volumes that can be measured by each probe type) . <br /> Press CHANGE. Enter the volume. Press ENTER to confirm your entry. The system displays : <br /> LOW PRODUCT: XXXXXX <br /> PRESS <STEP> TO CONTINUE <br /> 7- 17 <br />