COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2021 8:26:21 AM
Creation date
4/21/2021 9:51:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
21721070
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> DESIGNATED UNDERGROUND STORAGE TANK OPERATOR VISUAL INSPECTION REPORT ( Page 2 of 2) <br /> VII . INSPECTION HISTORY <br /> Has each follow- up action of Section III from the previous inspection been completed appropriately? Y N <br /> Attach documentation verifying appropriate service to this report. N ❑ <br /> VIII . ALARM HISTORY <br /> Attach a cony of the alarm history report1log report/logto this report. Y N INA <br /> Is the monitorings stem powered on and in proper operating mode? N ❑ ❑ <br /> Has each leak detection alarm since the previous inspection been responded to appropriately? ® ❑ ❑ <br /> Attach documentation verifying a oropriate service to this report. <br /> Have all containment sumps that have had a leak detection alarm since the previous inspection been responded to by a ® ❑ ❑ <br /> qualified UST Service Technician ? <br /> List below in Section 1X all containment sumps that have had a leak detection alarm since the previous inspection and have not been <br /> responded to by a qualified UST Service Technician . Containment sumps listed below require a visual inspection for damage, water, debris, <br /> hazardous substance, and proper sensor location . The results of the visual inspection must be recorded in Section IX. <br /> IX . UNDERGROUND STORAGE TANK SYSTEM INSPECTION <br /> Is the containment sump free of damage , water , debris , and hazardous substance? <br /> Containment Sump ID Y N Containment Sump ID Y N <br /> ❑ ❑ ❑ ❑ <br /> ❑ ❑ ❑ ❑ <br /> ❑ ❑ ❑ ❑ <br /> ❑ ❑ ❑ ❑ <br /> Are all sensors in containment sumps inspected located to detect a leak at the earliest opportunity ? ❑ ❑ <br /> Is the spill container free of damage , water , debris , and hazardous substance ? <br /> Tank ID 001 /Diesel /6 , 000 Gallons ® ❑ Tank ID ❑ ❑ <br /> Tank ID ❑ ❑ Tank ID ❑ ❑ <br /> Is the fill pipe free of obstructions ? <br /> Tank ID 001 /Diesel/6 , 000 Gallons ® ❑ Tank ID ❑ ❑ <br /> Tank ID I <br /> LlI ElI Tank ID ❑ El <br /> Is the fill cap securely on the fill pipe? <br /> Tank ID 001 /Diesel/6 , 000 Gallons 19 1 ❑ I Tank ID I ❑ ❑ <br /> Tank ID ❑ El Tank ID El FO <br /> Is the under-dispenser containment free of damage , water , debris , and hazardous substance? <br /> Under-Dispenser Containment ID Y N I NAI Under-Dispenser Containment ID Y N NA <br /> ❑ ❑ ❑ ❑ ❑ ❑ <br /> ❑ ❑ ❑ ❑ ❑ ❑ <br /> r❑ El ❑ El <br /> ❑ [I El El El El <br /> ❑ ❑ ❑ ❑ I ❑ ❑ <br /> ❑ ❑ ❑ ❑ ❑ ❑ <br /> Are all sensors in under-dispenser containment located to detect a leak at the earliest opportunity? 01 ❑ N <br /> X . TESTING AND MAINTENANCE Y N NA Date Last <br /> Performed <br /> Has the monitoring system certification been completed within the past 12 months ? ® ❑ 08/02/ 18 <br /> Has the spill container testing been completed within the past 12 months ? ® ❑ 08/02/ 18 <br /> Has the overfill prevention equipment inspection been completed within the past 36 months ? N ❑ ❑ 08/02/ 18 <br /> Has the secondary containment testing been completed within the past 36 months ? ® ❑ ❑ 08/24 / 17 <br /> Has the tank tightness testing been completed within required timeframes? ❑ ❑ N <br /> Has the line tightness testing been completed within the required timeframes ? ❑ ❑ N <br /> Other required testing / maintenance was completed within required timeframe . (List test/maintenance items below. ) <br /> Test / Maintenance : Cathodic Protection ® ❑ 08/23 / 17 <br /> Test / Maintenance : ❑ ❑ <br /> Test / Maintenance : ❑ ❑ <br /> Test / Maintenance : ❑ ❑ <br /> Test / Maintenance : ❑ ❑ <br /> Test / Maintenance : ❑ ❑ <br /> XI . FACILITY EMPLOYEE TRAINING Y N <br /> Have all individuals performing facility employee duties received the required facility employee training within the past 12 months ? N ❑ <br /> I the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> Y = Yes, N = No, NA = Not Applicable, ID = Identification <br />
The URL can be used to link to this page
Your browser does not support the video tag.