My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
324
>
2900 - Site Mitigation Program
>
PR0539852
>
WORK PLANS_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:20:02 AM
Creation date
4/21/2021 11:39:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
FileName_PostFix
PRE 2019
RECORD_ID
PR0539852
PE
2953
FACILITY_ID
FA0022798
FACILITY_NAME
TRACY OFFICE PLAZA
STREET_NUMBER
324
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23518005
CURRENT_STATUS
02
SITE_LOCATION
324 E ELEVENTH ST
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Workplan for Additional Assessment and Subslab Gas Sampling <br /> Tracy Office Plaza <br /> 324 E. 11th Street, Tracy,CA <br /> November 22,2013 <br /> Site Geology & Hydrogeology <br /> Soil from site borings consisted primarily of silty clay to a depth of approximately 5 to 9 ft bgs, underlain by <br /> more permeable sandy clays or clayey sands observed to a depth of approximately 25 ft bgs. Wet soil(possible <br /> groundwater) was encountered in the more permeable sandy clay or clayey sand layers encountered at <br /> approximately 8 to 11 ft bgs. Soil contamination is primarily located between 1 and 10 ft bgs based on field <br /> observations and analytical results. <br /> PROPOSED INVESTIGATION <br /> To identify the appropriate next steps at the site, Pangea discussed site conditions with the SJCEHD and <br /> reviewed the recently implemented Low Threat Closure Policy(LTCP)adopted by the State Water Resources <br /> Control Board. SJCEHD geologist Nuel Henderson requested additional source area assessment near boring <br /> B-I and the apparent subsurface piping from the former service station operations. Mr. Henderson also <br /> expressed concern that hydrocarbons could have migrated offsite and around prior offsite monitoring well <br /> MW-1 at the Tracy High School site. The prior benzene impacted detected in groundwater at the subject site <br /> and Tracy High School is illustrated on Figure 1.Additionally,monitoring well data forthe former Tracy High <br /> monitoring wells is included in Appendix B. If a significant source area is present,and if the residual impacts <br /> poses a vapor intrusion risk to the existing site building,Mr.Henderson believes source area removal could be <br /> appropriate. <br /> Our proposed scope of work to address these concerns is provided below. The objective of the proposed <br /> investigation is to install three onsite borings to define the lateral extent of contamination in soil and <br /> groundwater near boring B-1, and a contingent boring west of former Tracy High School well MW-1. To <br /> provide additional vertical delineation, one boring (B-7) will be continued to about 25 to 30 ft depth. To <br /> evaluate the potential for vapor intrusion into the onsite building, subslab gas sampling is proposed at two <br /> locations. Results of this investigation will be discussed with the SJCEHD and compared to media-specific <br /> criteria of the LTCP. <br /> Task 1 - Pre-Field Activities <br /> Prior to initiating field activities, Pangea will conduct the following tasks: <br /> • Obtain encroachment and excavation permits from the City of Tracy and drilling permits from <br /> SJCEHD as necessary; <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.