My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
31130
>
4400 - Solid Waste Program
>
PR0440003
>
CORRESPONDENCE_2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2021 2:42:13 PM
Creation date
4/21/2021 2:55:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2012
RECORD_ID
PR0440003
PE
4434
FACILITY_ID
FA0003698
FACILITY_NAME
CORRAL HOLLOW LANDFILL
STREET_NUMBER
31130
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303010
CURRENT_STATUS
01
SITE_LOCATION
31130 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440003_31130 CORRAL HOLLOW_2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 1 <br /> Natalia Subbotnikova ] <br /> From: Robert McClellon [EH] <br /> Sent: Tuesday, February 07, 2012 8:09 AM <br /> To: 'Michael Carroll' <br /> Cc: Natalia Subbotnikova[EH] <br /> Subject: Gas Probe Modifications <br /> Mike here are comments from Calrecycle staff: <br /> Hello Natalia: Thank you for forwarding the proposed revision to County landfills gas compliance wells. We do <br /> understand the Operator would like to reduce their purge time by inserting polyethylene tubes inside the existing <br /> PVC pipes. Based on Calrecycle's landfill gas monitoring procedures,we have recommended against purging <br /> the gas probes and have recommended readings once steady state has been achieved. Purging might actually <br /> defeat the purpose of true gas monitoring since by purging, gas that might have had the potential to migrate and <br /> accumulate within the probes will be purged. Our experience with polyethylene tubing is that they become brittle <br /> and break easily and there may not be a way to tell the condition of such plastic tubing once installed within the <br /> PVC. However, if the operator wants to install the plastic tubing, they should provide assurance that installing the <br /> plastic tubing will not defeat the purpose of gas monitoring and that it will not compromise the integrity of <br /> monitoring. <br /> Mike please address the comments so that we can get back to Calrecycle. Thanks Robert <br /> ')/7/2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.