Laserfiche WebLink
3 Set up Outlet Diffuser and Install Cleanout Plugs <br />0 Choose outlet location. <br />Side Outlet: <br />Go to Step 3b. <br />Straight <br />OR Through: <br />Go to Step 3c. <br />0 Reposition outlet diffuser (side outlets only) <br />y <br />1 f Or <br />Remove safety star insert, leave tethered to unit. Unscrew diffuser retaining nut and remove outlet <br />diffuser. Unscrew diffuser foot retaining nut and remove outlet diffuser foot. Rotate diffuser toward <br />chosen outlet, replace foot ensuring it will point to the back wall of the unit and hand tighten foot <br />retaining nut. Insert diffuser into chosen outlet and hand tighten retaining nut. <br />® Cap unused connections(all configurations) <br />OR Q �� OR <br />Screw in orovided 4" cleanout plugs using pipe thread <br />sealant or tape approved for use with plastics. Do not cap <br />the inlet or outlet connections attached to the diffusers. <br />page 6 of 10 Schier I GB -50 Installation Guide <br />