My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 10:55:49 AM
Creation date
4/29/2021 10:35:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J D AR I N Environmental Health Department <br /> TUU ;,�j i y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: FDat,-.Arco.Am pm 83333 550 W Valpico Rd, Tracy ber 20, 2021 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 108 CCR 2620(b); HSC 25284(a)(3)Failure to implement or maintain a written agreement between the UST owner and <br /> operator. <br /> OBSERVATION: The annual operating permit is not issued to the current operator and there is no written <br /> agreement between the person who was issued the permit and the operator to monitor the UST system.A Letter <br /> from Chief Financial Officer letter was uploaded in place of an Owner/Operator Written Agreement. <br /> REGULATION GUIDANCE: If a permit is issued to a person other than the operator of the tank, that person shall <br /> enter into a written agreement with the operator of the tank to monitor the UST system. <br /> CORRECTIVE ACTION: This was corrected on site via CERS. The Letter from Chief Financial Officer was removed <br /> from the Owner/Operator section and that section was changed to'exempt'. <br /> This is a minor violation. <br /> 308 CCR 2632(c), 2634(d), 2636(f) Failure of the leak detection equipment to have an audible and visual alarm. <br /> OBSERVATION: The 304 sensor(1-16)in UDC 15/16 failed to activate an audible and visual alarm when tested to <br /> ensure continuous monitoring of the tank system. <br /> REGULATION GUIDANCE:All monitoring equipment shall be maintained to activate an audible and visual alarm or <br /> stop the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: The sensor was replaced and retested during the inspection.This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> All violations were corrected on site during the inspection. No further follow up is required. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> Documents provided during inspection: list of free CUPA classes <br /> Inspection report was emailed to Edgar Rizkallah, diamondpetroleum1@yahoo.com <br /> FA0020989 PR0536555 SCO01 10/20/2021 <br /> EHD 23-01 Rev.9/16/2020 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.