My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0505735
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2021 9:47:38 AM
Creation date
4/30/2021 2:49:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0505735
PE
2361
FACILITY_ID
FA0006972
FACILITY_NAME
TSI TRANS SYSTEM INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19332008
CURRENT_STATUS
01
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />5/26/2021 <br />Underground Storage Tank Program Inspection Report <br />Date: <br />May 21, 2021 <br /> Facility Address: <br /> 707 E ROTH RD, FRENCH CAMP <br /> Facility Name: <br /> TSI TRANS SYSTEM INC <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 109 CCR 2715(a)(1)(B), 2715(a)(3) Failure to submit "Designated Underground Storage Tank Operator Identification <br />Form" within 30 days. <br />OBSERVATION: A new designated operator, Marissa Murphy, began conducting inspections on 11-18-2020 and <br />notification was not provided to the EHD within 30 days of the change. <br />REGULATION GUIDANCE: The owner or operator shall submit a "Designated Underground Storage Tank Operator <br />Identification Form" no later than 30 days after any change in the designated UST operator(s). <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br />This is a repeat violation, Class II. <br /> 203 CCR 2712(b)(1-2) Failure to maintain monitoring records for 36 months and maintenance records for 60 months. <br />OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br />- Overfill prevention equipment inspection results <br />REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br />include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance <br />records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs <br />of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br />inventory readings and reconciliations. <br />CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the <br />last three years on site. <br />This is a repeat violation, Class II. <br />FA0006972 PR0505735 SC001 05/21/2021 <br />EHD 23-01 Rev. 9/16/2020 Underground Storage Tank Program OIRPage 4 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.