Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> COUNT <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SAFEWAY FUEL CENTER#2707 6425 N PACIFIC AVE, STOCKTON May 13, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 307 HSC 25290.1(c3), 25290.2(c3) Failure to keep water out of the secondary containment system (post-Jul 2003). <br /> OBSERVATION: Liquid was observed in the following locations: <br /> -Approximately 2 cups of liquid in the 87 fill sump <br /> -Approximately a half gallon of liquid in the 87 turbine sump <br /> REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration, it <br /> must be removed and disposed of properly. <br /> CORRECTIVE ACTION: Immediately remove this liquid, make a hazardous waste determination per Title 22 <br /> hazardous waste regulations, and manage it accordingly. Ensure that all sumps and annular spaces are maintained <br /> free of liquid. <br /> This is a Class II violation. <br /> 317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow. <br /> OBSERVATION: The 91 and diesel line leak detectors failed to detect a leak when tested. <br /> REGULATION GUIDANCE:All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. <br /> CORRECTIVE ACTION: Immediately have a properly licensed,trained, and certified contractor repair or replace the <br /> failed leak detector(LG 113-x listed, if applicable)and obtain a permit within one business day from the EHD, if <br /> needed. If the failed leak detector can't be replaced immediately,there is a possibility that the 91 and diesel UST <br /> system may be red tagged to prevent fuel inputs. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by June 14, 2021. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> Documents provided during inspection: Return to Compliance certification, flyer for free CUPA classes <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: May 13, 2021 Inspector: Inspector Phone: <br /> Printed Name and Title: LYDIA BAKER, REHS (209)616-3046 <br /> Emailed to Keith Powers, Environmental Compliance Manage <br /> FA0002409 PR0231211 SCO01 05/13/2021 <br /> EHD 23-01 Rev.9/16/2020 Page 5 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />