My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7272
>
2300 - Underground Storage Tank Program
>
PR0231939
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2023 1:01:54 PM
Creation date
5/4/2021 8:10:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231939
PE
2361
FACILITY_ID
FA0002570
FACILITY_NAME
QUIK STOP MARKET #144
STREET_NUMBER
7272
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
094-040-13
CURRENT_STATUS
01
SITE_LOCATION
7272 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALTON <br />ENGINEERING, INC. <br />Overfill Prevention Inspection - OPW 61 and 71 Series Devices <br />Date: 7/22/2021 <br />Owner: QSM#144 <br />Facility: 7272 WEST LN <br />OPW Overfill Model Number: 61/71 SO <br />Part 1 - Proper Height Setting Calculation <br />Part 2 - Device Certification Criteria Evaluation <br />Does the overfill prevention device meet the 95% <br />requirement? <br />Yes <br />Tank 1 <br />Tank 2 <br />Tank 3 <br />Tank 4 <br />Maximum Tank Volume Per: <br />A Gallons <br />9684 <br />9684 <br />7841 <br />Max shut off requirement for flapper is 95% <br />B 95% <br />95 <br />95 <br />95 <br />Multiply Max tank volume by 95% <br />c Gallons <br />9200 <br />9200 <br />7448 <br />Yes <br />Use tank chart or ATG to determine height of <br />movement, weakening due to wear and corrosion <br />calculated volume <br />D Inches <br />803/8 <br />803/8 <br />80 1/4 <br />Measure top of fill riser threads, or face seal <br />adapter <br />E Inches <br />32 <br />33 <br />36 <br />Tank diameter (From Tank Chart) <br />F Inches <br />893/4 <br />893/4 <br />893/4 <br />Upper Tube in Tank (G) F -D = G <br />G Inches <br />93/8 <br />93/8 <br />91/2 <br />Subtract 2" from upper tube in tank G-2"= K <br />K Inches <br />73/8 <br />73/8 <br />71/2 <br />Calculated minimum upper tube length (I) <br />K+E=I <br />I Inches <br />393/8 <br />403/8 <br />431/2 <br />Actual measured upper tube length (Without <br />fill adapter) <br />J Inches <br />403/4 <br />41 3/4 <br />443/4 <br />Part 2 - Device Certification Criteria Evaluation <br />Does the overfill prevention device meet the 95% <br />requirement? <br />Yes <br />Yes <br />Yes <br />Is the actual measured upper tube length 6.5 inches or <br />Yes <br />Yes <br />Yes <br />more than the fill riser? (J must be 6.5" or more than E) <br />Does the overfill prevention device function as required? <br />(Inspect the device for damage, contamination, freedom of <br />Yes <br />Yes <br />Yes <br />movement, weakening due to wear and corrosion <br />Device Overfill Certification PASS / FAIL <br />PASS <br />PASS <br />PASS <br />Drop Tube Testing PASS / FAIL <br />PASS <br />PASS <br />PASS <br />Technician certifies that the device is operationally compliant. <br />Signature of Technician:MAXWELL HINES <br />Technician's Name: MAXWELL HINES <br />Date: 7/23/21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.