My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 10:47:59 AM
Creation date
5/4/2021 9:08:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Overfill Prevention Equipment InSDection Report Form <br />6. OVERFILL PREVENTION EQUIPMENT DETAILS <br />Tank ID (One OPEpercolumn) <br />87 <br />91 <br />DSL <br />Are both vent and tank riser piping <br />❑ Yes <br />❑ Yes <br />❑ Yes <br />❑ Yes <br />secondarily contained? <br />® No <br />® No <br />® No <br />❑ No <br />OPE Model <br />EBW <br />EBW <br />EBW <br />Tank Manufacturer <br />Mod Weld <br />Mod Weld <br />Mod Weld <br />® Shuts off <br />® Shuts off <br />® Shuts off <br />❑ Shuts off <br />Flow <br />Flow <br />Flow <br />Flow <br />What is the OPE response when <br />® Restricts <br />® Restricts <br />® Restricts <br />❑ Restricts <br />activated? <br />Flow <br />Flow <br />Flow <br />Flow <br />(Check all that apply.) <br />❑ Audible <br />❑ Audible <br />❑ Audible <br />❑ Audible <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />❑Visual <br />❑Visual <br />❑Visual <br />❑Visual <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />Are flow restrictors installed on vent <br />E] Yes <br />E] Yes <br />E] Yes <br />❑Yes <br />piping that may interfere with the OPE <br />®No <br />®No <br />®No <br />El No <br />operation? <br />At what level in the tank is the OPE set to <br />79" <br />84" <br />84" <br />activate? (Inches from bottom of tank) <br />What is the percent capacity of the tank in <br />90% <br />94% <br />94% <br />which the OPE activates? <br />Is the OPE in proper operating condition <br />® Yes <br />® Yes <br />® Yes <br />❑ Yes <br />to respond when the stored substance <br />❑ No <br />❑ No <br />❑ No <br />❑ No <br />reaches the designated regulatory level. <br />7. SUMMARY OF TESTING RESULTS <br />OPE Inspection Results <br />® Pass <br />® Pass <br />® Pass <br />❑ Pass <br />❑ Fail <br />❑ Fail <br />❑ Fail <br />❑ Fail <br />8. COMMENTS <br />Retested drop tubes with correct tank charts. All tests passed. Inspector on site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.