My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 10:47:59 AM
Creation date
5/4/2021 9:08:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEAK TEST METHOD <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />EVRrSETUP <br />UP <br />_ <br />TEST ON DATE : ALL TANK <br />ISD DEGRD PRES FAIL <br />V <br />JUL 1. 2009 <br />ISD VAPOR LEAK. FAIL <br />START TIME : DISABLED <br />ISD VP PRES FAIL <br />ISD VP STATUS'FHIL <br />EVR TYPE: VACUUM ASSIST <br />TEST RATE :0.20 GAL/HR <br />ISD SETUP FAIL <br />VACUUM ASSIST TYPE <br />DURATION 2 HOURS <br />ISD SENSOR OUT FAIL <br />HEALY VAC <br />TST EARLY STOP:DISABLED, <br />ISD HOSE ALARMS <br />ArL RANGE <br />LEAK TEST REPORT FORMAT <br />ALL:GROSS COLLECT FAIL <br />MAX: 1.15 MIN: 0.95 <br />NORMAL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />VAPOR PROCESSOR TYPE - <br />NONE <br />R 2:PREM <br />TYPE: <br />STANDARD <br />ANALYSIS TIMES <br />NORMALLY CLOSED <br />TIME: 8:00 AM <br />DELAY MINUTES: 1 <br />TANK #: 2 <br />ACCEPT HIGH ORVR: <br />LIQUID SENSOR ALMS <br />ENABLED <br />LIQUID SENSOR SETUP <br />L 3:FUEL ALARM <br />ISD.HOSE TABLE <br />_ _ _ - - - _ _ - _ - - <br />L 5:FUEL ALARM <br />ID FP FL HL AA RR <br />L 3:SENSOR OUT ALARM <br />L 1:UNL STP <br />L 5:SENSOR OUT ALARM <br />------------------------ <br />01 01 01 02 01 02 <br />TRI-STATE (SINGLE FLOAT) <br />L 3:SHORT ALARM <br />L 5:SHORT ALARM <br />02 02 02 02 01 02 <br />CATEGORY : STP SUMP <br />03 03 03 02 02 02 <br />ISD SITE ALARMS <br />04 04 04 02 02 02 <br />L 2:UNL ANN <br />ISD GROSS PRES FAIL <br />TRI-STATE (SINGLE FLOAT) <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD AIRFLOW METER MAP <br />CATEGORY ANNULAR SPACE <br />ISD VP PRES FAIL <br />ID SERIAL NUM LABEL <br />_____ <br />ISD VP STATUS FAIL <br />- <br />1 35166 1-2 ISD <br />ISD SETUP FAIL <br />2 29308 3-4 ISA <br />L 3:FREM STP <br />ISD SENSOR OUT FAIL <br />TRI-STATE (SINGLE FLOAT) <br />ALARMS <br />ISD HOSHLL:GRE A <br />CATEGORY': STP SUMP <br />COLLECT PHIL <br />ISD FUEL GRADE HOSE MAP <br />ALL:DEGRD COLLECT FAIL <br />1 2. 3 4 <br />FF MHH MHH tMHH HA <br />L 4:DIESEL STP <br />ALL:FLOW COLLECT FAIL <br />------------------------ <br />TRI-STATE (SINGLE FLOAT) <br />R 3:DIESEL <br />01,201 901 101 U •U 1 <br />CATEGORY : STP SUMP <br />TYPE: <br />02 202 902 102 U U 1. <br />STANDARD <br />03 203 903 103 3 U 2. <br />CLOSED <br />04 204 904 104 3 U 2 <br />L 5:PREM-DSL.ANNNORMALLY <br />.,.TRI-STATE (SINGLE'FLOAT) <br />TANK #: 3 <br />-CATEGORY ANNULAR SPACE <br />LABEL TABLE <br />------------------------- <br />LIQUID SENSOR ALMS <br />1: UNASSIGNED <br />2: BLEND3 <br />L 4:FUEL ALARM <br />3: REGULAR <br />L 5:FUEL ALARM <br />4: MID GRADE <br />L 4:SENSOR OUT ALARM <br />5: PREMIUM <br />L 5:SENSOk OUT ALARM <br />6: GOLD <br />L 4:SHORT ALARM <br />7: BRONZE <br />L 5:SHORT ALARM <br />8: SILVER <br />9: BLEND2 <br />10: BLEND4 <br />OUTPUT RELAY SETUP <br />R I:UNL <br />TYPE: <br />STHNDHRD <br />NORMALLY CLOSED <br />SMARTSENSOR SETUP <br />TANK. # : 1 <br />s 1:1-2 ISD <br />LIQUID SENSOR ALMS <br />CATEGORY AIR FLOW METER <br />L I:FUEL ALARM <br />s 2:3-4 ISD <br />L 2: FUEL ALARM <br />1:SENSOR OUT ALARMi <br />CATEGORY AIR FLOW METERL <br />L 2:SENSOR OUT ALARM <br />s 8:3-4 VAPGRPRESS <br />L 1:SHORT ALARM <br />L 2:SHORT ALARMCATEGORY <br />VAPOR PRESSURE <br />' <br />