My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1972-1986
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
14750
>
4400 - Solid Waste Program
>
PR0440007
>
CORRESPONDENCE_1972-1986
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2021 5:21:37 PM
Creation date
5/7/2021 8:41:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1972-1986
RECORD_ID
PR0440007
PE
4434
FACILITY_ID
FA0000595
FACILITY_NAME
HARNEY LANE LANDFILL
STREET_NUMBER
14750
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06503006
CURRENT_STATUS
01
SITE_LOCATION
14750 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Memo to Antonia Vorster -2- 21 April 1986 <br /> second to verify a southerly gradient before drilling the east and west <br /> wells. Whichever well (or wells) on the site becomes the upgradient well <br /> must be placed far enough away from the landfill that it would not pick up <br /> any leachate from the landfill if it were to occur. <br /> 3. To ensure that accurate ground water elevations are determined as ground <br /> water is encountered, proposed well locations must be surveyed before <br /> drilling begins, and a monument should be established near each well site. <br /> Elevations of completer) wells must subsequently be determined to a 0.01 <br /> foot accuracy. <br /> 4. At each quarterly sampling, ground water levels in the wells must be <br /> determined prior to purging or sampling. In accordance with Section 2556 <br /> A.4 of Subchapter 15, ground water contours, ground water velocity, and <br /> direction of flow must be plotted on a site map and submitted each quarter <br /> to the Regional Board. <br /> 5. The proposed casing hammer/dual tube reverse circulations air rotary <br /> drilling procedure looks like a good method for logging the hole and <br /> identifying water-bearing zones. If foam is to be used, will the geologist <br /> on-site be able to identify the water-bearing zones? Air should be <br /> filtered to prevent oil from the compressor from entering the wells. <br /> 6. Proposed materials for well construction are acceptable. Slotted pipe <br /> should be installed at least two feet above highest expected water levels. <br /> The sand backfill , bentonite pellets, and cement grout should be installed <br /> using a tremie pipe to prevent bridging. Will water by added to the <br /> bentonite pellets after placement or will they be mixed with a cement grout <br /> prior to placement? Filter pack design must be compatible with both the <br /> screen sizing and the geologic materials in the screened zones. <br /> 7. The proposed sampling program is acceptable. What quality control/quality <br /> assurance procedures are proposed? <br /> JLE:Jec <br />
The URL can be used to link to this page
Your browser does not support the video tag.