Laserfiche WebLink
Field Flow <br /> Job Description: 10498 S.Airport Rd,Manteca <br /> Contact: James Barnard <br /> Prepared by: RBM <br /> Date: 21-Mar-21 <br /> Please fill in the shaded areas and drop down menus: <br /> This spreadsheet serves as a guide,and is not a complete hydraulic design. <br /> Worksheet 1- Field Flow <br /> Total field <br /> Total Quantity of effluent to be disposed per day 00 gallons/day <br /> Hydraulic loading rate gallons/s .ft./da <br /> Total Dispersal Field Area 2,000 square ft. <br /> Flow per zone <br /> Number of Zones 1 zone(s) <br /> Dispersal area per one 2,000 square ft. <br /> Choose linespacing between WASTEFLOW lines 2 ft. <br /> Choose emitterspacing between WASTEFLOW emitt 2 ft. <br /> Total linear ft.per zone(minimum required) 1,000 ft.per zone <br /> Total number of emitters per zone 500 emitters per zone <br /> Select Wasteflow dripline(16mm) Wasteflow PC-1/2gph driphne <br /> Pressure at the beginning of the dripfield 30 psi <br /> Feet of Head at the beginning of the dripfield 69.3 ft. <br /> What is the flow rate per emitter in gph? 0.53 gph <br /> Dose flow per zone 4.42 Igpm <br /> Note: A few States or Counties require additional flow for flushing. Please check your local regula <br /> Flush velocity in this spreadsheet below is for PC dripline only. Classic dripline usually requires les <br /> Please refer to Geoflow's spreadsheet called"Design Flow and Flush Curves"at www.geoflow.com <br /> If required,choose flush velocity ft sec <br /> How many lines of WASTEFLOW per zone? lines <br /> Fill in the actual length of longest dripline lateral ft. <br /> Max.allowable length of a single WASTEFLOW line 200 ft. <br /> Flush flow required at the end of each dripline 0.37 gpm <br /> Total Flow required to achieve flushing velocity 3.70 gpm <br /> Total Flow per zone-worst case scenario 8.12 gpm <br /> Select Filters and zone valves <br /> Select pipe diameters for manifolds and submains 1.25 inch <br /> Select Filter Type BioDisc Filter <br /> Recommended Filter(item no.) BioDisc-150 <br /> Select Zone Valve Type None - <br /> Recommended Zone Valve item no. 0 <br /> Check below to choose quantity and length of daily doses <br /> Dosin <br /> Number of doses per day/zone: doses <br /> Timer ON.Pump run time per dose/zone: 8:00 mins:secs <br /> Timer OFF. Pump off time between doses 0:52:00 hrs:mins <br /> Per Zone-Pump run time per day/zone: 8:00 hrs:mins <br /> All Zones-Number of doses per day/all zones 12 doses/day <br /> All Zones-Pump run time per day/all zones: 0.33 hrs:mins <br /> Geoilow,Inc. Wasteflow Design Spreadsheet V.2003H 3/25/2021 <br />