My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2700
>
3000 – Underground Injection Control Program
>
PR0009077
>
SITE INFORMATION AND CORRESPONDENCE_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2021 3:15:46 PM
Creation date
5/11/2021 1:18:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3000 – Underground Injection Control Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
PRE 2019
RECORD_ID
PR0009077
PE
2960
FACILITY_ID
FA0004038
FACILITY_NAME
ARCO BULK FACILITY
STREET_NUMBER
2700
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
2700 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1010
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Maintenance Data Ozone Sparge System-Operations and Maintenance STTC-West System <br /> Field Data Sheet 3003 Navy Drive <br /> Stockton,California <br /> Frequency Item to Inspect or Maintain Date Performed <br /> Monthly to Bi-mon€hty Check panel vent air filters(2). Clean or replace as necessary ) <br /> _ - ......... ..............................._...._. _... — -. __.. <br /> Monthly to Bi-monthly Check Feed Gas Air Dryer filter bowl. A find dust may develop over time on the filter,but no <br /> moisture should be present in the bowl. If moisture is present contact us. <br /> . ........... <br /> Check Feed Gas Air Dryer inside the system control panel: Red light should cycle on and <br /> Monthly to Bi-month#y off every few minutes,when exhaust gas is discharged. If exhaust air discharge is on <br /> continuously,contact us. <br /> — — — ......... ... ... ..... _. -- — - <br /> Monthly to Bi monthly Check all lines for moisture-ensure that the air compressor system is feeding dry air to the <br /> ozone generator panel <br /> _.. .... <br /> Monthly to Bs monthly Check HMI(touch screen)for system alarms and verify operation.- <br /> ..... tg �� <br /> -- - <br /> Bi-weekly Check integr€ty of all hoses Wings,piping,and valves ({j <br /> Bi-weekly Inspect electrical fittings and tighten as needed <br /> -61--weekly.-. Check controller operation � �� <br /> As-Needed Adjust controller program <br /> Bi-weekly Check flow and pressure on assemblies(system and wells) <br /> ... .._ -- - - - ......... <br /> Bi-weekly Fake ozone readings at compound and well boxes <br /> - ................... .- - -- - .................. — <br /> Bi-weekly Take FID Readings <br /> 13i-weekly Check wellhead connections <br /> Bi-weekly Check/test all safety override systems <br /> ...—..... <br /> Bi-weekly Measure Compressor Running Amperage <br /> Bi-weekly Check Compressor Oil <br /> As-Neeeded — — <br /> - <br /> Clean Com ressor inlet Filter <br /> Catcon Systems: 925-277-0665 <br /> NOTES AND DESCRIPTION OF ACTIVITIES ON SITE <br /> Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.