My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2017-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREWERT
>
916
>
4400 - Solid Waste Program
>
PR0526865
>
CORRESPONDENCE_2017-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2024 11:30:21 AM
Creation date
5/11/2021 1:39:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2017-2018
RECORD_ID
PR0526865
PE
4443
FACILITY_ID
FA0018195
FACILITY_NAME
CENTRAL VALLEY COMPOST
STREET_NUMBER
916
Direction
W
STREET_NAME
FREWERT
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19126022
CURRENT_STATUS
01
SITE_LOCATION
916 W FREWERT RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
274
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
y � • <br /> I <br /> GOVERNOR <br /> CALIFORNIA <br /> St.ItHEY!RODn10UE2 <br /> Water Boards [/ ERVIROHME iDR <br /> ,rj`/ EIIVIROHMENTPL PROTEC 11011 <br /> Central Valley Regional Water Quality Control Board ,► <br /> 1ED <br /> 20 September 2018 .r e 4 2018 <br /> Adam +_iV1;1{UNM <br /> Harvest PoweorrCaliforrnia, LLC.egulatory ompliance Coordinator PQ*TSERIqC7 <br /> 6943 North Golden State Blvd <br /> Fresno, CA 93722 <br /> DEFICIENCIES IN FINAL PLANS, SPECIFICATIONS,AND CONSTRUCTION QUALITY <br /> ASSURANCE(CQA) PLAN;HARVEST POWER CALIFORNIA, LLC;HARVEST-LA THROP <br /> COMPOSTING FACILITY; SAN JOAQUIN COUNTY <br /> On 2 July 2018 Harvest Power California, LLC (Discharger) submitted Site Improvement Plans <br /> for construction of improvements at the Discharger's Harvest-Lathrop's Composting Facility. <br /> The Site Improvement Plans were submitted to comply with Water Quality Order 2015-0121- <br /> DWQ, General Waste Discharge Requirements for Composting Operations (General Order) and <br /> the Discharger's Notice of Applicability (NOA) issued to the Discharger on 7 February 2018 by <br /> the Central Valley Regional Water Quality Control Board (Central Valley Water Board). On 7 <br /> August 2018, Central Valley Water Board staff notified the Discharger that it must include a <br /> construction quality assurance plan (CQA Plan)that ensures that construction proceeds in <br /> accordance with approved plans and specifications. On 17 August 2018, the Discharger <br /> provided final grading plans for the site improvements. On 23 August 2018, the Discharger <br /> provided CQA plans for earthwork(Soil CQA Plan)'and geosynthetics (Geosynthetic CQA Plan). <br /> On 28 August 2018, Central Valley Water Board staff notified the Discharger via email that the <br /> Discharger must include construction specifications that ensure that the construction contractor <br /> meets specifications required to ensure that the construction will meet the design requirements. <br /> On 10 September 2018, the Discharger submitted construction plans (Plans), construction <br /> specifications (Specifications), and construction quality assurance plans (CQA Plans)for review <br /> and approval. <br /> Central Valley Regional Water Quality Control Board (Central Valley Water Board) staff have <br /> reviewed the Plans, Specifications, and CQA Plans submitted on 10 September 2018 and have <br /> identified the following deficiencies which need to be addressed prior to issuance of an <br /> approval: <br /> i <br /> A. Critical Deficiencies: <br /> i <br /> 1. Subsurface PVC Drainage Pipe Elevations.The Plans (sheet 2 of 7) PVC drainage <br /> pipe elevations do not incorporate elevations specified in the Pipe Drainage Ditch <br /> Detail shown on Plans (sheet 3 of 7). The detail shows the crown of the PVC pipe j <br /> installed 2.5 feet below finish grade. However, sheet 2 of 7 shows the crown of PVC <br /> pipe at approximately finish grade elevation. j <br /> 2. Detail of Drop Inlets and connection to PVC Drainage Pipe. The Plans do not 1 <br /> provide details for the Drop Inlets and how they will be connected to the subsurface <br /> PVC Drainage Pipe. <br /> 3. Specifications and CQA for assembly of large diameter PVC pipes. Proper <br /> assembly and installation of large diameter PVC pipe in the field requires <br /> KARL E. LONGLEY SCD,P.E.,CHAIR I PATRICK PULUPA,ESO.,EXECUTIVE OFFICER <br /> 11020 Sun Center Drive 4200,Rancho Cordova,CA 95670 1 wwvi.waterboards.ca.gov/centralvalley <br /> Cd RECYCLED PAPER <br />
The URL can be used to link to this page
Your browser does not support the video tag.