Laserfiche WebLink
ATTACHMENT B F-11 NA PLAN FIELD <br /> ONSHORE OIL PRODUCTION FACILITIES-40 CFR 112.9 <br /> (Drilling and workover facilities are excluded from the requirements of§112.9) <br /> Production facility means all structures(including but not limited to wells,platforms,or storage facilities),piping(including but not limited to flowlines or <br /> intra-facility gathering lines),or equipment(including but not limited to workover equipment,separation equipment,or auxiliary non-transportation- <br /> related equipment)used in the production,extraction, recovery, lifting,stabilization,separation or treating of oil(including condensate),or associated <br /> storage or measurement,and is located in an oil or gas field,at a facility.This definition governs whether such structures, piping,or equipment are <br /> subject to a specific section of this part. <br /> 112.9(b) Oil Production Facility Drainage <br /> (1) At tank batteries, separation and treating areas where there is a ❑ Yes ❑No❑ NA ❑ Yes❑No❑NA <br /> reasonable possibility of a discharge as described in §112.1(b), <br /> drains for dikes or equivalent measures are closed and sealed <br /> except when draining uncontaminated rainwater.Accumulated oil <br /> on the rainwater is removed and then returned to storage or <br /> disposed of in accordance with legally approved methods <br /> Prior to drainage, diked area inspected and action taken as <br /> provided below: <br /> • 112.8(c)(3)(ii)- Retained rainwater is inspected to ensure that ❑ Yes ❑No ❑NA ❑ Yes❑No❑NA <br /> its presence will not cause a discharge as described in <br /> §112.1(b) <br /> • 112.8(c)(3)(iii)-Bypass valve opened and resealed under ❑ Yes ❑No❑NA ❑ Yes D No❑NA <br /> responsible supervision <br /> • 112.8(c)(3)(iv)-Adequate records of drainage are kept;for ❑ Yes ❑No❑NA ❑ Yes ❑No❑NA <br /> example, records required under permits issued in <br /> accordance with§122.410)(2)and (m)(3) <br /> (2) Field drainage systems(e.g., drainage ditches or road ditches)and ❑ Yes ❑No❑NA ❑ Yes❑No ❑NA <br /> oil traps, sumps, or skimmers inspected at regularly scheduled <br /> intervals for oil, and accumulations of oil promptly removed <br /> 112.9(c)Oil Production Facility Bulk Storage Containers <br /> Bulk storage container means any container used to store oil.These containers are used for purposes including,but not limited to,the storage of oil <br /> prior to use,while being used,or prior to further distribution in commerce.Oil-filled electrical,operating,or manufacturing equipment is not a bulk <br /> storage container. <br /> (1) Containers materials and construction are compatible with material ❑ Yes❑No ❑NA ❑ Yes❑No❑NA <br /> stored and conditions of storage such as pressure and temperature <br /> (2) Except as allowed for flow-through process vessels in §112.9(c)(5) ❑ Yes ❑No❑NA ❑ Yes❑No❑NA <br /> and produced water containers in §112.9(c)(6), secondary <br /> containment provided for all tank battery, separation and treating <br /> facilities sized to hold the capacity of largest single container and <br /> sufficient freeboard for precipitation. <br /> Drainage from undiked area safely confined in a catchment basin ❑ Yes❑No❑NA ❑ Yes❑No❑NA <br /> or holding pond. <br /> (3) Except as allowed for flow-through process vessels in §112.9(c)(5) ❑ Yes❑No❑NA ❑ Yes❑No❑NA <br /> and produced water containers in §112.9(c)(6), periodically and <br /> upon a regular schedule, visually inspect containers for <br /> deterioration and maintenance needs, including foundation and <br /> supports of each container on or above the surface of the ground <br /> (4) New and old tank batteries engineered/updated in accordance with ❑ Yes❑No❑NA ❑ Yes❑No❑NA <br /> good engineering practices to prevent discharges including at least <br /> one of the following: <br /> • Adequate container capacity to prevent overfill if a • Adequate vacuum protection to prevent container collapse;or <br /> pumper/gauger is delayed in making regularly scheduled . High level sensors to generate and transmit an alarm to the <br /> rounds; computer where the facility is subject to a computer production <br /> • Overflow equalizing lines between containers so that a control system <br /> full container can overflow to an adjacent container; <br /> Comments: <br /> Tier 1 Qualified Facilities Page B-1 of 4 June 2014 <br />