My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231289
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2021 9:22:51 AM
Creation date
5/19/2021 8:03:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231289
PE
2361
FACILITY_ID
FA0003847
FACILITY_NAME
WEST LANE FUEL
STREET_NUMBER
3300
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11705037
CURRENT_STATUS
01
SITE_LOCATION
3300 N WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VAPOR VALVE THERMOMETER TEST <br />7.3.2 <br />Vapor polisher ambient temperature <br />74.32 <br />Vapor polisher outlet temperature <br />73.45 <br />Difference between ambient and outlet temperatures <br />0.87 <br />Is the difference less than 10° F? If not, proceed to section 9.2.1 <br />Yes <br />Is the difference less than 10° F? If not, proceed to section 9.1 <br />9.2.2 <br />Vapor polisher ambient temperature <br />Vapor polisher outlet temperature <br />Difference between ambient and outlet temperatures <br />Is the difference less than 10° F? If not, proceed to section 9.2.4 <br />No <br />T5 temperature <br />9.2.4 & 9.2.5 <br />Vapor polisher ambient temperature <br />84.925 <br />Vapor polisher outlet temperature <br />1.268 <br />Calibrated thermometer ambient temperatures <br />Yes <br />9.1 <br />Difference between outlet temperature and the calibrated thermometer <br />Is the difference less than 10° F? If not, the outlet thermometer does not meet specifications <br />No <br />Difference between ambient temperature and the calibrated thermometer <br />Is the difference less than 10° F? If not, the ambient thermometer does not meet specifications <br />UST THERMOMETER TEST <br />Iff:7-UST #1 <br />7.3.3 <br />T5 temperature <br />85.441 <br />T4 temperature <br />82.780 <br />Difference between T5 and T4 temperatures <br />2.661 <br />Is the difference less than 10° F? If not, proceed to section 9.1 <br />Yes <br />9.1 <br />T5 temperature <br />Calibrated thermometer ambient temperature <br />Difference between T5 and calibrated thermometer <br />Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br />UST #2 <br />7.3.3 <br />T5 temperature <br />86.193 <br />T4 temperature <br />84.925 <br />Difference between T5 and T4 temperatures <br />1.268 <br />Is the difference less than 10° F? If not, proceed to section 9.1 <br />T5 temperature <br />Yes <br />9.1 <br />Calibrated thermometer ambient temperature <br />Difference between T5 and calibrated thermometer <br />Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br />I declare, under penalty of perjury under the laws of the state of California that based on information and belief formed after reasonable inquiry, the statements and <br />information provided in this document are true, accurate, and complete. <br />Ver. 1.1 — 01.20.09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.