Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike,PO Box 12425,Lancaster,PA 17605-2425•717-656-2300 Fax 717-656-2681•www.lancasterlabs.com <br /> Page 4 of 5 <br /> Quality Control Summary <br /> Client Name: Chevron Environmental Mgmt Co Group Number: 1203973 <br /> Reported: 09/14/10 at 02:00 PM <br /> Surrogate Quality Control <br /> 6037219 101 99 101 99 <br /> 6037220 102 101 101 100 <br /> 6037221 102 97 100 101 <br /> 6037222 102 102 101 102 <br /> Blank 99 103 101 100 <br /> LCS 101 100 100 101 <br /> MS 102 97 100 101 <br /> MSD 102 102 101 102 <br /> Limits: 77-114 74-113 77-110 78-110 <br /> Analysis Name: PAHs in Water by LVI GC/MS <br /> Batch number: 10204WAE026 <br /> Nitrobenzene-6 2-Fluorobiphenyl TerphenyIA14 <br /> 6037217 124 105 90 <br /> 6037218 125 102 90 <br /> 6037219 137 96 89 <br /> 6037220 132 103 89 <br /> 6037221 124 104 83 <br /> 6037222 127 105 86 <br /> Blank 110 94 84 <br /> LCS 119 101 80 <br /> MS 124 104 83 <br /> MSD 127 105 86 <br /> Limits: 69-144 76-149 61-150 <br /> Analysis Name: TPH-DRO water C10-C25 <br /> Batch number: 102030012A <br /> Orthoterphenyl <br /> 6037217 91 <br /> 6037218 89 <br /> 6037219 95 <br /> 6037220 93 <br /> 6037221 105 <br /> 6037222 127* <br /> Blank 87 <br /> LCS 105 <br /> LCSD 109 <br /> MS 105 <br /> MSD 127* <br /> Limits: 45-114 <br /> Analysis Name: TPH-DRO water C10-C25 w/Si Gel <br /> Batch number: 102140002A <br /> Orthoterphenyl <br /> 6037219 78 <br /> Blank 77 <br /> LCS 86 <br /> LCSD 89 <br /> Limits: 45-114 <br /> *-Outside of specification <br /> (1)The result for one or both determinations was less than five times the LOQ. <br /> (2)The unspiked result was more than four times the spike added. <br />