Discussion of Soil Litho/ogy <br /> Based on the soil observed in the borings, there appears to be moderate potential for <br /> percolation in the shallow soil zone and good potential for percolation in the deep soil <br /> zone at the test location. Sandy soils generally have a much greater potential for <br /> percolation than fine-grained or cemented soils. However, a percolation test is the only <br /> accepted method for determining the suitability of the soils for a septic disposal area. <br /> Percolation test results are discussed in the following section. <br /> Percolation Test <br /> A shallow and deep percolation test was conducted in the proposed septic disposal <br /> area of the Site. The soil borings discussed above were used for the percolation test <br /> holes. Percolation test procedures conformed to San Joaquin County Environmental <br /> Health Department policy. <br /> Preparation and Presaturation of Percolation Test Holes <br /> After the borings were advanced by hand auger and the soil logged, the test holes were <br /> completed for the percolation testing. Approximately two inches of pea gravel were <br /> placed in the bottom of each open soil boring, followed by a 2.0-inch diameter PVC pipe <br /> with perforations on the bottom. Pea gravel was then used to backfill a few inches of <br /> the annular space. <br /> Live Oak presaturated the percolation test holes approximately 24 hours prior to the <br /> percolation testing. Each hole was filled with water to a height of 12 inches above the <br /> bottom of the boring for the presaturation. On the day of testing, both holes were found <br /> to be intact and dry. <br /> Percolation Test Procedure <br /> Live Oak conducted the percolation test for the borings on March 11, 2021. Due to <br /> initial percolation rates observed, a four-hour test was selected. Water level <br /> measurements were taken every 30 minutes during the four-hour period. The last 30 <br /> minutes of the test were observed by Aldara Salinas, Registered Environmental Health <br /> Specialist at the San Joaquin County Environmental Health Department. <br /> An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, each hole was refilled with water <br /> to a level of approximately six inches above the bottom of the hole. <br /> LOGE 2107 Page 6 <br />