Laserfiche WebLink
Stantec <br /> L & M OPERABLE UNIT- FOURTH QUARTER AND ANNUAL 2012 SITE STATUS, <br /> REMEDIAL SUMMARY, AND GROUNDWATER MONITORING REPORT <br /> Groundwater Monitoring and Sampling <br /> February 1, 2013 <br /> Analyte Sample# Sample# % Difference <br /> MW-9 QCDUP-1 <br /> TPHg (mg/L) 0.82 1.2 +/-37.6% <br /> TPHd (mg/L) 2.8 3.5 +/-22.2% <br /> TPHo (mg/L) 0.071 0.089 +/-22.5% <br /> Benzene (mg/L) 0.0058 0.0099 +/- 52.2% <br /> MtBE (mg/L) 0.00098 0.0011 +/- 11.5% <br /> TBA (mg/L) 0.028 0.032 +/- 13.3% <br /> A relative percent difference (RPD) for TPHg, TPHd, TPHo, and benzene are estimated at 37.6, <br /> 22.2, 22.5, and 52.2 percent, respectively, during 4Q12. The RPD values for TPHg, TPHd, <br /> TPHo, and benzene are greater than the recommended range of RPD (20 percent) for quality <br /> control (QC) purposes. This may indicate a possible bias for reproducibility and precision. The <br /> TPHg, TPHd, TPHo, and benzene analytical results are within historical values; therefore, the <br /> reported values are not anticipated to be affected. <br /> 2.3.2.5 General Laboratory Notes <br /> The following validation issues are consistent with the shallow zone quality assurance (QA) and <br /> QC. Each set of issues corresponds directly with the denoted report (Appendix E). <br /> Validation issues with report number 82960: <br /> The matrix spike (MS) and matrix spike duplicate (MSD) and RPD values associated with <br /> sample QCEB-2-RM for the analyte benzene were outside of the stated QC limits. The sample <br /> was affected by the analyte concentrations already present in the un-spiked sample. This may <br /> indicate a possible bias for the reporting accuracy and precision. The laboratory control spike <br /> (LCS) percent recovery was within QC limits indicating accuracy in reporting. Since there is no <br /> RPD value to confirm precision in reporting, the reported benzene may be biased; however, <br /> benzene values are within historical limits. <br /> The MS/MSD associated with samples QCDUP-4, QCTB-1, QCTB-2, QCEB-1-PV, QCEB-2-PV, <br /> and QCEB-1-RM for the analyte P + M xylene was outside of the stated QC limits for percent <br /> recovery. This may indicate a possible bias for the reporting accuracy. The LCS percent <br /> recovery was within QC limits indicating accuracy in reporting. RPD values were within QC <br /> range in the MSD indicating precision in reporting. The reported values are considered valid. <br /> 2.4 FOURTH QUARTER 2012 B-ZONE GROUNDWATER RESULTS <br /> 2.4.1 B-Zone Groundwater Gradient <br /> B-Zone groundwater elevations at the Site ranged from 6.34 ft below MSL in well MW-35 to <br /> 1.28 ft above MSL in well MW-44 (Table 3 and Figure 10). Groundwater gradient during 4Q12 <br /> in the B-Zone was calculated for two sections of the site (central and western). Along the <br /> I:\Tidewater\TW Stockton(P2A)\QMRs\2012\4Q12-Ann ual\4Q12 and Annual QSSR QRSR QMR Stockton_FINAL.doc 2.5 <br />