My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2003-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
14750
>
4400 - Solid Waste Program
>
PR0440007
>
CORRESPONDENCE_2003-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2021 10:58:50 AM
Creation date
5/21/2021 8:59:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2003-2004
RECORD_ID
PR0440007
PE
4434
FACILITY_ID
FA0000595
FACILITY_NAME
HARNEY LANE LANDFILL
STREET_NUMBER
14750
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06503006
CURRENT_STATUS
01
SITE_LOCATION
14750 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 2 <br /> LFG System Evaluation <br /> Harney Lane Landfill <br /> LFG Collection Piping Evaluation <br /> Maximum Factor <br /> Pipe Actual Flow Design Flow of <br /> Pipe Application Size (in) Rate (cfm) Rate (cfm) Safety Note <br /> Well lateral with one well 3 20.5 60 2.9 1 <br /> Well lateral serving three wells 3 30.75 60 2.0 2 <br /> Header 6 155.8 375 2.4 3 <br /> Main header into flare station 8 410 800 2.0 <br /> Blower Evaluation <br /> Vacuum Available -60 in. we <br /> Vacuum Needed -14 in. we <br /> Factor of Safety 4.3 <br /> Flow Rate Available 1300 cfm <br /> Flow Rate Needed 410 cfm <br /> Factor of Safety 3.2 <br /> Base Data <br /> LFG system flow rate 410 cfm (as of November 2004) <br /> Number of LFG wells 80 <br /> Average flow rate per well 5.1 cfm <br /> Notes <br /> 1 The flow rate from an individual well is assumed to be four times the average well flow rate. <br /> 2 The combined flow rate from any three wells is assumed to be six times the average well flow rate. <br /> 3 The flow rate through a header is assumed to be proportional to the landfill area served by that header. <br /> Maximum area served by a single header is equivalent to one-half of the 85 acre Primary Site, or <br /> approximately 38%of the total landfill area (112 ac). <br /> in.we=inches water column pressure <br /> NAlHarney Lane\LFG Other\MitigPlan04\SystEvaI04.xis,PipeSelect Printed 11/19/2004 <br />
The URL can be used to link to this page
Your browser does not support the video tag.