Laserfiche WebLink
Oeurofins Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike,PO Box 12425,Lancaster,PA 17605-2425•717-656-2300 Fax:717-656-2681•www.lancasteriabs.com <br /> Page 3 of 3 <br /> Quality Control Summary <br /> Client Name: Chevron Environmental Mgmt Co Group Number: 1334716 <br /> Reported: 09/29/12 at 09:58 AM <br /> Surrogate Quality Control <br /> Surrogate recoveries which are outside of the QC window are confirmed <br /> unless attributed to dilution or otherwise noted on the Analysis Report. <br /> Analysis Name: VOCs 25 ml purge 8260 <br /> Batch number: H122571AA <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 6784191 96 93 107 96 <br /> 6784192 96 95 107 96 <br /> 6784193 96 95 106 93 <br /> Blank 96 96 107 94 <br /> LCS 96 95 107 99 <br /> LCSD 96 94 106 98 <br /> Limits: 77-114 74-113 77-110 78-110 <br /> Analysis Name: PAHs in Water by LVI GC/MS <br /> Batch number: 1225SWACO26 <br /> Nitrobenzene-d5 2-Fluorobiphenyl Terphenyl-d14 <br /> 6784191 105 95 81 <br /> 6784192 106 90 74 <br /> Blank 95 94 90 <br /> LCS 95 87 73 <br /> LCSD 108 97 80 <br /> Limits: 52-149 55-151 45-127 <br /> Analysis Name: TPH-DRO water C10-C25 <br /> Batch number: 122560008A <br /> Orthoterphenyl <br /> 6784191 96 <br /> 6784192 94 <br /> Blank 95 <br /> LCS 108 <br /> LCSD 111 <br /> Limits: 45-114 <br /> *-Outside of specification <br /> **-This limit was used in the evaluation of the final result for the blank <br /> (1)The result for one or both determinations was less than five times the LOQ. <br /> (2)The unspiked result was more than four times the spike added. <br />