Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike,PO Box 12425,Lancaster,PA 17605-2425•717-656-2300 Fax:717-656-2681•www.lancasterlabs.com <br /> Page 1 of 2 <br /> Lancaster Laboratories Sample No. WW 4527428 <br /> SB-22-W-35-050517 Grab Water <br /> Vernalis Pump Station SAIC <br /> 35500 Welty Vernalis NA SB-22 <br /> Collected:05/17/2005 11:45 by LI Account Number: 11413 <br /> Submitted: 05/19/2005 08 :55 Chevron Environmental Mgt. Co. <br /> Reported: 06/09/2005 at 14 :12 P.O. Box 6012, Room K-2066 <br /> Discard: 07/10/2005 San Ramon CA 94583 <br /> SB225 SDG#: OVQ20-07 <br /> As Received <br /> CAT As Received Method Dilution <br /> No. Analysis Name CAS Number Result Detection Units Factor <br /> Limit <br /> 01728 TPH-GRO - Waters n.a. N.D. 50. ug/l 1 <br /> The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRO range <br /> start time. <br /> The vial submitted for volatile analysis did not have a pH < 2 at the time <br /> of analysis. Due to the volatile nature of the analytes, it is not <br /> appropriate for the laboratory to adjust the pH at the time of sample <br /> receipt. The pH of this sample was pH = 7. <br /> 06609 TPH-DRO CALUFT(Waters) n.a. 780. 150. ug/l 1 <br /> Sample quantitation was performed using the total sample area from C10 <br /> through C25 as requested by the client. <br /> Due to the nature of the sample matrix, a reduced aliquot was used <br /> for analysis. The reporting limits were raised accordingly. <br /> 06610 TPH-DRO CALUFT(Water) w/Si Gel n.a. N.D. 150. ug/l 1 <br /> Due to the nature of the sample matrix, a reduced aliquot was used <br /> for analysis. The reporting limits were raised accordingly. <br /> The recovery of DRO in the LCS and LCSD associated with this sample is outside <br /> the QC acceptance limits. The samples were reextracted and reanalyzed, however, <br /> the LCS/LCSD were outside the QC limits again. Since there is no sample <br /> remaining, the first trial is reported. Similar sample results were observed. <br /> 08357 Selected SVOAs by 8270 SIM <br /> 08362 Naphthalene 91-20-3 N.D. 0.05 ug/l 1 <br /> 08365 Acenaphthylene 208-96-8 N.D. 0.1 ug/l 1 <br /> 08366 Acenaphthene 83-32-9 N.D. 0.05 ug/l 1 <br /> 08368 Fluorene 86-73-7 N.D. 0.05 ug/l 1 <br /> 08369 Phenanthrene 85-01-8 N.D. 0.05 ug/l 1 <br /> 08370 Anthracene 120-12-7 N.D. 0.1 ug/l 1 <br /> 08372 Fluoranthene 206-44-0 N.D. 0.05 ug/l 1 <br /> 08373 Pyrene 129-00-0 N.D. 0.1 ug/l 1 <br /> 08374 Benzo(a)anthracene 56-55-3 N.D. 0.1 ug/l 1 <br /> 08375 Chrysene 218-01-9 N.D. 0.1 ug/l 1 <br /> 08376 Benzo(b)fluoranthene 205-99-2 N.D. 0.1 ug/l 1 <br /> 08377 Benzo(k)fluoranthene 207-08-9 N.D. 0.05 ug/l 1 <br /> 08378 Benzo(a)pyrene 50-32-8 N.D. 0.1 ug/l 1 <br /> 08379 Indeno(1,2,3-cd)pyrene 193-39-5 N.D. 0.1 ug/l 1 <br /> 08380 Dibenz(a,h)anthracene 53-70-3 N.D. 0.1 ug/l 1 <br /> 08381 Benzo(g,h,i)perylene 191-24-2 N.D. 0.1 ug/l 1 <br /> 06053 BTEX by 8260B <br />