Laserfiche WebLink
TABLE B-1 <br /> SUMMARY OF QUALIFIED DATA <br /> VERNALIS PUMP STATION <br /> Vernalis,California <br /> SDG/ <br /> Lancaster Result <br /> Field Sample ID Report Number Lab Sample ID Sample Purpose Matrix Parameter (ug/L) MDL LOQ Qualifier Reason Code Reason for Qualification <br /> Naphthalene 0.032 0.0099 0.049 J N04 Result is between the MDL and LOQ <br /> QA-Pump-R-080409 1086177 5330404 Equipement Rinsate Blank Water Indo(1,2,3-cd)pyrene N.D. 0.0099 0.049 E P02 The LCS/LCSD recovery was below the lower control limit <br /> Benzo(g,h,i) perylene N.D. 0.0099 0.049 1 E P02 The LCS/LCSD recovery was below the lower control limit <br /> Naphthalene 0.031 0.01 0.05 J N04 Result is between the MDL and LOQ <br /> MW-6-W-080409 1086177 5330405 Field Sample Water Indo 1,2,3-cdpyrene N.D. 0.01 0.05 E P02 The LCS/LCSD recovery was below the lower control limit <br /> Benzo(g,h,i) perylene N.D. 0.01 0.05 E P02 The LCS/LCSD recovery was below the lower control limit <br /> Naphthalene 0.018 0.0099 0.05 J nN04 <br /> Result is between the MDL and LOQ <br /> MW-7-W-080409 1086177 5330408 Field Sample Water Indo(1,2,3-cd)pyrene N.D. 0.0099 0.05 E The LCS/LCSD recovery was below the lower control limit <br /> Benzo ,h,i e leve N.D. 0.0099 0.05 E The LCS/LCSD recovery was below the lower control limit <br /> Acenaphthene 0.018 0.0099 0.01 J Result is between the MDL and LOQ <br /> MW-7-W-080717 1100978 5416850 Field Sample Water TPH-DRO(C10-C25) 320 50 100 E Field Duplicate RPD were>30%for water <br /> TPH-DRO(C10-C25)W/SiGel 170 50 100 E Q01 Field Duplicate RPD were>30%for water <br /> MW-7-WD-080717 1100978 5416851 Field Duplicate Water TPH-DRO(C10-C25) 230 50 100 E Q01 Field Duplicate RPD were>30%for water <br /> TPH-DRO(C10-C25)W/SiGel 68 50 100 E Q01 Field Duplicate RPD were>30%for water <br /> MW-3-W-080717 1101231 5418147 Field Sample Water TPH-DRO(C10-C25) N.D. 50 100 E H02 MS recovery was below the lower control limit <br /> TPH-DRO(C10-C25) N.D. 50 100 E COS I Continuing calibration percent difference was not acceptable. <br /> TPH-DRO(C10-C25) 110 50 130 E H02 MS recovery was below the lower control limit <br /> MW-2-W-080717 1101231 5418148 Field Sample Water TPH-DRO(C10-C25) 110 50 130 J N04 Result is between the MDL and LOQ <br /> TPH-DRO(C10-C25) 110 50 130 E C05 Continuing calibration percent difference was not acceptable. <br /> MW-5-W-080717 1101231 5418149 Field Sample Water TPH-DRO(C10-C25) N.D 50 100 E H02 MS recovery was below the lower control limit <br /> TPH-DRO(C10-C25) N.D 50 100 E C05 Continuing calibration percent difference was not acceptable. <br /> MW-5-WD-080717 MS 1101231 5418150 Matrix Spike Water TPH-DRO(C10-C25) 390 50 100 E H02 MS recovery was below the lower control limit <br /> TPH-DRO(C10-C25) 390 50 100 E C05 Continuing calibration percent difference was not acceptable. <br /> MW-5-WD-080717MSD 1101231 5418151 Matrix Spike Duplicate Water TPH-DRO(C10-C25) 510 50 100 E H02 MS recovery was below the lower control limit <br /> TPH-DRO(C10-C25) 510 50 100 E C05 Continuing calibration percent difference was not acceptable. <br /> Abbreviations: <br /> TPH-DRO=Total Petroleum Hydrocarbon-diesel <br /> E=Indicates the reported value is estimated due to associated quality control results <br /> J=Indicates the reported value is an estimated concentration detected between the MDL and LOQ <br /> LCS=Laboratory control sample LCSD=Laboratory control sample duplicate <br /> LOQ=Limit of quantitation <br /> MDL=Method detection limit <br /> MS=Matrix spike <br /> MSD=Matrix spike duplicate <br /> RPD=Relative percent difference <br /> SDG=Sample delivery group <br /> gg/L=Micrograms per liter <br /> Note:Units are in mg/kg for soil matrix and gg/L for water <br /> ,— <br /> Page 1 of 1 Flom science to snru!lms <br />