My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WELTY
>
35500
>
2900 - Site Mitigation Program
>
PR0508043
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2021 7:04:54 PM
Creation date
5/24/2021 11:28:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0508043
PE
2960
FACILITY_ID
FA0007905
FACILITY_NAME
CHEVRON PIPELINES
STREET_NUMBER
35500
STREET_NAME
WELTY
STREET_TYPE
RD
City
VERNALIS
Zip
95385
APN
25526003
CURRENT_STATUS
01
SITE_LOCATION
35500 WELTY RD
P_LOCATION
99
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1915
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> GEOMATRIX <br /> J TPH quantified as gasoline(TPHg)has not been detected in the groundwater samples collected <br /> 1 from monitoring wells MW-2, MW-3,.and MW-4 (Table 4). TPHd concentrations exceeding <br /> 100 micrograms per liter(ttg/L)have not been detected in the groundwater samples collected <br /> l from MW-2, MW-3, and MW-4 since November 1998. The estimated lateral extent of TPHd <br /> concentrations in groundwater exceeding 100 gg/L is shown on Figure 4. <br /> 2.2 INVESTIGATION OBJECTIVES AND APPROACH <br /> After a review of the results of the 2002 investigation (Geomatrix, 2002a),the RWQCB <br /> requested additional assessment of the vertical and lateral extent of affected soil and <br /> l groundwater, specifically at depths greater than 45 feet bgs in the vicinity of SB-14 and at <br /> 1 off-site locations hydraulically downgradient of the Bellini property. In response to the <br /> RWQCB request, ChevronTexaco submitted a work plan(Geomatrix, 2003a), which was <br /> `] subsequently approved by the RWQCB (2003a). <br /> -� In August 2003, Geomatrix conducted a soil and grab groundwater investigation at the site. <br /> Sampling locations are shown on Figure 3. Specific objectives and approach of the sampling <br /> -1 program are summarized as follows: <br /> JAssess the lateral and verKcal extent of petroleum hydrocarbons in soil <br /> ' (Section 2.3.1). Four borings (SB-15 through SB-17 and SB-21), including one <br /> contingency step-out boring, were advanced at on-site(Former Vernalis Pump <br /> Station) locations. Three borings (SB-18 through SB-20)were advanced at <br /> downgradient, off-site locations. <br /> �. Characterize the petroleum hydrocarbons in shallow soil(Section 2.3.1). Shallow <br /> soil samples were collected from on-site borings SB-15, SB-16, SB-17, and SB-21 <br /> to characterize the type and concentrations of petroleum constituents in soil at <br /> -� depths of less than or equal to 10 feet bgs at the site. <br /> • Assess the lateral and vertical extent of petroleum hydrocarbons in groundwater <br /> (Section 2.3.2). Grab groundwater samples were collected from borings SB-15, <br /> SB-17, SB-18, and SB-21 to assess the presence of petroleum constituents in <br /> 1 groundwater at and downgradient of the site. <br /> `J 2.3 FIELD AND ANALYTICAL METHODS <br /> Prior to conducting field activities, Geomatrix obtained boring permits from the San Joaquin <br /> County Public Health Service(SJC-PHS) and Stanislaus County and an encroachment permit <br /> from the California Department of Transportation (Appendix A). Underground Service Alert <br /> (USA) and Cruz Brothers Sub-Surface Locators, Inc., of Milpitas, California, were notified to <br /> 4 perform an underground utility clearance at each boring location. Soil boring, grab <br /> CNROJECIl5000SM 1.000\5011-03.d.c 5 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.