Laserfiche WebLink
TABLE B-1 <br /> SUMMARY OF QUALIFIED DATA <br /> VERNALIS PUMP STATION <br /> Vernalis,California <br /> Lab Result MDL LOQ Reason <br /> Field Sample ID Sample ID Sample Purpose Matrix Parameter (pg/L) (pg/L) (µg/L) Qualifier Code Reason for Qualification <br /> MW-7-W-061107 4911461 Field Sample Groundwater TPHd 130 50 100 E F03 Sample data were qualified as a result of the <br /> equipment rinsate <br /> Flourene 0.01 0.01 0.05 J N04 Result is between the MDL and LOQ <br /> Naphthalene 0.027 0.01 0.05 J N04 Result is between the MDL and LOQ <br /> MW-6-W-061107MS 4911458 Matrix Spike Groundwater Indeno(1,2,3-cd)pyrene 122 0.02 E PO1 LCS recovery was above upper contol limit <br /> Benzo(g,h,i)perylene 120 0.02 E PO1 LCS recovery was above upper contol limit <br /> Dibennz(a,h)anthracene 124 0.02 E HO1 MS/MSD recovery was above the upper <br /> control limit <br /> MW-6-W-061107MSD 4911459 Matrix Spike Duplicate Groundwater Indeno(1,2,3-cd)pyrene 122 0.02 E PO1 LCS recovery was above upper contol limit <br /> Benzo(g,h,i)perylene 120 0.02 E PO1 LCS recovery was above upper contol limit <br /> Indeno(1,2,3-cd)pyrene 117 0.02 E HO1 MS/MSD recovery was above the upper <br /> control limit <br /> Dibenz(a,h)anthracene 121 0.02 E HO1 MS/MSD recovery was above the upper <br /> control limit <br /> Abbreviations: <br /> E=Indicates the reported value is estimated due to associated quality control results. <br /> ID=Identification <br /> J=Indicates the reported value is an estimated concentration detected between the MDL and LOQ <br /> LOQ=Limit of quantitation <br /> MDL=Method detection limit <br /> TPHd=Total petroleum hydrocarbons as diesel-range organics,carbon range C10-C25 <br /> gg/L=Micrograms per liter <br /> Page 1 of 1 <br />