Field Duplicate <br /> Sample MW-3-WD-090211 is a field duplicate of MW-3-W-090211. RPDs were <br /> calculated for analytes that were detected in both the field duplicate and parent sample. <br /> All calculated RPDs were below the control limit of 30 percent, with two exceptions: the <br /> RPD for phenanthrene and fluoranthene were 32 percent and 34 percent, respectively, in <br /> the field duplicate pairs. This indicates that phenanthrene and fluoranthene were <br /> relatively non-homogenous, as compared to other parameters measured in the field <br /> duplicate pair. Therefore, the results are qualified E. <br /> MS/MSDs <br /> Project-specific MS and MSD samples were collected with samples as part of this data <br /> set. The MS and MSD for PAHs could not be evaluated because the laboratory <br /> performed a 100x dilution before analysis due to matrix interference. The spike was not <br /> recovered in the MS and MSD analyzed for TPHd and TPHd with silica gel analyses. <br /> The laboratory re-extracted the MS and MSD for the TPHd with silica gel analyses <br /> because of associated low surrogates and LCS, and the recoveries were again low in the <br /> second analysis. This indicates a matrix effect may have biased the sample results. The <br /> results for TPHd and TPHd with silica gel were qualified E in samples MW-3-W-090211 <br /> and MW-3-WD-090211. <br /> REPRESENTATIVENESS <br /> Representativeness was assessed through the evaluation of method blank samples, trip <br /> and equipment blank samples, chain-of-custody forms,preservation, and holding times. <br /> Method Blank Results <br /> Target analytes were not detected in any laboratory method blanks. <br /> Field Quality Control Results <br /> Equipment rinsate blank QA-Boiler-R-090211 was submitted with the samples. This was <br /> a rinsate of the bailer used. No target analytes were detected. <br /> Chain-Of-Custody Forms <br /> Sample analytical results were evaluated for agreement with the chain-of-custody form. <br /> The evaluation determined that all samples were received at the laboratory in the <br /> appropriate containers and in good condition with the chain-of-custody form filled out <br /> properly. <br /> Preservation and Holding Times <br /> All samples were received at the laboratory within the acceptance temperature criterion <br /> of 4 +2 °C and were analyzed within specified holding times. <br /> Reporting Limits <br /> Data reported for this sampling event were reported with the program specified reporting <br /> limits for groundwater samples. The program reporting limits were used to report data <br /> below the applicable action levels. Reporting limits were raised for PAHs in MW-3-W- <br /> 090211 and field duplicate MW-3-WD-090211 because the laboratory diluted the sample <br /> before analysis for matrix interference. <br />