Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike,PO Box 12425,Lancaster,PA 17605-2425-717-656-2300 Fax:717-656-2681•www.larcasterIabs.com <br /> Page 3 of 3 <br /> REVISED <br /> Quality Control Summary <br /> Client Name: Chevron Environmental Mgt. Co. Group Number: 1105765 <br /> Reported: 09/12/08 at 12:39 PM <br /> Surrogate Quality Control <br /> Nitrobenzene-d5 2-Fluorobiphenyl Terphenyl-d14 <br /> 5443251 90 126 108 <br /> 5443253 100 115 118 <br /> 5443254 114 126 105 <br /> 5443255 118 121 114 <br /> 5443256 153 144* 71 <br /> 5443257 3116* 143* 129 <br /> 5443258 93 130 142 <br /> Blank 88 129 137 <br /> LCS 94 123 113 <br /> MS 114 126 105 <br /> MSD 118 121 114 <br /> Limits: 64-161 62-134 61-150 <br /> Analysis Name: TPH-DRO(C10-C25)Water w/ SiGel <br /> Batch number: 082490003A <br /> Orthoterphenyl <br /> 5443253 66 <br /> 5443254 93 <br /> 5443255 72 <br /> 5443256 81 <br /> 5443257 691* <br /> Blank 76 <br /> LCS 83 <br /> MS 93 <br /> MSD 72 <br /> Limits: 59-131 <br /> Analysis Name: EPA SW846/8260 (water-25ml) #1 <br /> Batch number: L082341AA <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 5443251 106 90 90 85 <br /> 5443252 105 91 90 84 <br /> 5443253 98 90 90 87 <br /> 5443254 95 86 97 90 <br /> 5443255 94 87 97 89 <br /> 5443256 108 93 87 91 <br /> 5443257 102 90 98 103 <br /> 5443258 99 88 91 84 <br /> Blank 104 91 91 86 <br /> LCS 99 86 96 95 <br /> MS 95 86 97 90 <br /> MSD 94 87 97 89 <br /> Limits: 77-114 74-113 77-110 78-110 <br /> *-Outside of specification <br /> (1)The result for one or both determinations was less than five times the LOQ. <br /> (2)The unspiked result was more than four times the spike added. <br />