Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike,PO Box 12425,Lancaster,PA 17605-2425-717-656-2300 Fax:717-656-2681•www.larcasterIabs.com <br /> Page 1 of 2 <br /> Lancaster Laboratories Sample No. WW5536930 Group No. 1121309 <br /> SB-29-W-36-081120 Grab Water <br /> US Can - Welty Road SAIC <br /> Vernalis, CA NA SB-29 <br /> Collected:11/20/2008 12:00 by SS Account Number: 11413 <br /> Submitted: 11/21/2008 09:10 Chevron Environmental Mgt. Co. <br /> Reported: 12/09/2008 at 11:13 6111 Bollinger Canyon Rd <br /> Discard: 01/09/2009 BR1Y3432 <br /> San Ramon CA 94583 <br /> VE-29 SDG#: OVV57-02 <br /> As Received <br /> CAT As Received Program Dilution <br /> No. Analysis Name CAS Number Result RL Units Factor <br /> 06912 TPH-DRO (C10-C25) water n.a. 74,000 830 ug/1 25 <br /> The observed sample pattern includes #2 fuel/diesel and an additional <br /> pattern which elutes later in the DRO range. <br /> 06913 TPH-DRO water C10-C25 w/Si Gel n.a. 58,000 830 ug/1 25 <br /> The observed sample pattern is not typical of #2 fuel/diesel. It elutes in <br /> the DRO range later than #2 fuel. <br /> 06570 PAHs in Water by LVI GC/MS <br /> 06576 Naphthalene 91-20-3 14 0.30 ug/l 10 <br /> 06579 Acenaphthylene 208-96-8 N.D. # 0.20 ug/l 10 <br /> 06580 Acenaphthene 83-32-9 6.5 0.30 ug/l 10 <br /> 06581 Fluorene 86-73-7 28 0.30 ug/l 10 <br /> 06582 Phenanthrene 85-01-8 45 0.30 ug/l 10 <br /> 06583 Anthracene 120-12-7 2.7 0.30 ug/l 10 <br /> 06584 Fluoranthene 206-44-0 2.3 0.30 ug/l 10 <br /> 06585 Pyrene 129-00-0 3.4 0.30 ug/l 10 <br /> 06586 Benzo(a)anthracene 56-55-3 1.2 0.30 ug/l 10 <br /> 06587 Chrysene 218-01-9 5.4 0.20 ug/l 10 <br /> 06588 Benzo(b)fluoranthene 205-99-2 1.3 0.30 ug/l 10 <br /> 06589 Benzo(k)fluoranthene 207-08-9 N.D. # 0.30 ug/l 10 <br /> 06590 Benzo(a)pyrene 50-32-8 N.D. # 0.30 ug/l 10 <br /> 06591 Indeno(1,2,3-cd)pyrene 193-39-5 N.D. # 0.40 ug/l 10 <br /> 06592 Dibenz(a,h)anthracene 53-70-3 0.32 0.30 ug/l 10 <br /> 06593 Benzo(g,h,i)perylene 191-24-2 0.58 0.40 ug/l 10 <br /> Due to the nature of the sample matrix, a reduced aliquot was used for <br /> analysis. The reporting limits were raised accordingly. <br /> Due to the sample matrix an initial dilution was necessary to perform the <br /> analysis. Therefore, the reporting limits for the GC/MS semivolatile <br /> compounds were raised. <br /> 02898 EPA SW846/8260 (water-25ml) #1 <br /> 02942 Benzene 71-43-2 N.D. 0.1 ug/l 1 <br /> 02965 Toluene 108-88-3 N.D. 1.0 ug/l 1 <br /> 02976 Ethylbenzene 100-41-4 N.D. 1.0 ug/l 1 <br /> 02900 EPA SW846/8260 (water-25ml) #3 <br /> 05308 Xylene (Total) 1330-20-7 N.D. 1.0 ug/l 1 <br /> #=Laboratory MethodDetection Limit exceeded target detection limit <br /> N.D.=Not detected at or above the Reporting Limit. <br />