Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike,PO Box 12425,Lancaster,PA 17605-2425-717-656-2300 Fax:717-656-2681•www.larcasterIabs.com <br /> Page 2 of 2 <br /> Quality Control Summary <br /> Client Name: Chevron Environmental Mgt. Co. Group Number: 1122197 <br /> Reported: 12/11/08 at 09:46 PM <br /> Surrogate Quality Control <br /> Surrogate recoveries which are outside of the QC window are confirmed <br /> unless attributed to dilution or otherwise noted on the Analysis Report. <br /> Analysis Name: TPH-DRO water C10-C25 <br /> Batch number: 083360000A <br /> Orthoterphenyl <br /> 5542392 87 <br /> Blank 77 <br /> LCS 94 <br /> LCSD 90 <br /> Limits: 45-114 <br /> Analysis Name: PAHs in Water by LVI GC/MS <br /> Batch number: 08336WABO26 <br /> Nitrobenzene-d5 2-Fluorobiphenyl Terphenyl-d14 <br /> 5542392 84 96 89 <br /> Blank 68 100 98 <br /> LCS 71 93 89 <br /> LCSD 73 98 89 <br /> Limits: 64-161 62-134 61-150 <br /> Analysis Name: EPA SW846/8260 (water-25ml) #1 <br /> Batch number: C083391AA <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 5542391 101 103 96 88 <br /> 5542392 100 103 95 89 <br /> Blank 100 101 96 87 <br /> LCS 100 100 97 90 <br /> LCSD 99 98 97 90 <br /> MS 101 101 97 96 <br /> Limits: 77-114 74-113 77-110 78-110 <br /> *-Outside of specification <br /> (1)The result for one or both determinations was less than five times the LOQ. <br /> (2)The unspiked result was more than four times the spike added. <br />