Attachment B: Data Usability Summary and Laboratory Chemical Analytical Report <br /> Preservation and Holding Times <br /> Samples were preserved in the field as appropriate,were received at the laboratory within the <br /> acceptance temperature criterion of 4+2 °C, and were prepared and analyzed within specified <br /> holding times. The sample preservations,when required by the analysis,were less than the <br /> acceptance pH limit of 2. <br /> Laboratory Fuel Notes for TPHd Analysis <br /> The laboratory noted that the observed hydrocarbon fuel pattern for TPHd analysis in sample <br /> WFSMW-I-W-060503, and its field duplicate WFSMW-I-WD-060503, included#2 fuel/diesel <br /> and an additional pattern that elutes later in the target carbon range. Individual peaks also eluted <br /> within the target carbon range. TPHd were reported at 190 gg/L in sample WFSMW-I-W- <br /> 060503, and 160 µg/L in field duplicate sample WFSMW-I-WD-060503. The samples were also <br /> silica-gel cleaned prior to the analysis and TPHd were not detected after the silica-gel cleanup. <br /> This indicates the TPHd results were likely biased high due to biogenic material,which was <br /> removed during silica-gel analysis. <br /> Completeness <br /> Completeness is defined as the number of valid results(i.e.,those not rejected)divided by the <br /> total number rejected. Based on this evaluation of the data against the QC objectives,the <br /> percentages of valid data for each method and matrix are 100 percent. <br /> Comparability <br /> Based on the data evaluation, it was concluded that the data are comparable with other laboratory <br /> data for similar samples and sample conditions. The sample collection techniques,EPA test <br /> methods, detection limits, analytical laboratory,units of measure, and sample preparation <br /> procedures were selected to ensure data comparability. <br /> Summary <br /> Based on SAIC's evaluation, all analytical data are usable as qualified for the purpose of <br /> determining chemical concentrations in groundwater at the site. <br /> The result for naphthalene detected in the equipment rinsate blank,QA-R-060503,was qualified J <br /> because the concentration was between the laboratory MDL and reporting limit. The final result <br /> for this sample is 0.019 Jµg/L. <br /> Unless noted otherwise,analytical data collected in support of this investigation are considered <br /> precise, accurate,representative, complete, and comparable, and they may be used for their <br /> intended purposes. <br />